validade preditiva de equações de referência para força de preensão manual em homens brasileiros de meia idade e idosos predictive validity of reference equations to hand grip strength in brazilian men of middle age and elderly

validade preditiva de equações de referência para força de preensão manual em homens brasileiros de meia idade e idosos predictive validity of reference equations to hand grip strength in brazilian men of middle age and elderly

;Alex de Andrade Fernandes;Cristiano Diniz da Silva;Breno Cesar Vieira;João Carlos Bouzas Marins
linear algebra and its applications 2012 Vol. 19 pp. 351-356
252
fernandes2012fisioterapiavalidade

Abstract

O objetivo deste estudo foi verificar a validade preditiva das equações de referência para predição da força de preensão manual (FPM) em homens brasileiros de meia idade e idosos. Foram avaliados 60 homens com idade de 58,7±8,6 anos (50-84 anos), estatura 168,7±8,0 cm, massa corporal 67,9±13,0 kg e índice de massa corporal 23,7±4,0 kg/m², utilizando equipamento 'padrão-ouro' na avaliação da FPM e seguindo todas as recomendações metodológicas preconizadas pela American Society of Hand Therapists (ASHT). Os resultados do diagrama de Bland-Altman para mão dominante (MD) apresentam um erro médio (viés) de -8,4% (IC95% -51,6-34,7). Já o diagrama de Bland-Altman para mão não dominante (MND) apresenta um erro médio (viés) de 1,4% (IC95% -47,1-49,8). O cálculo de Cronbach's alpha para a MD foi de 0,69 e 0,59 para MND. O coeficiente de correlação intraclasse para MD foi 0,52 (IC95% 31-68) e de 0,42 (IC95% 20-60) para a MND. Concluímos que as equações para predição analisadas neste estudo, para uma população de homens brasileiros de meia idade e idosos, apresentou baixa validade preditiva, o que pode gerar erros de interpretação dos resultados.
The objective of this study was to verify the predictive validity of reference equations for hand grip strength (HGS) in middle-aged and elderly Brazilian men. We evaluated 60 men with age of 58.7±8.6 years, height 168.7±8.0 cm, body mass 67.9±13.0 kg, and body mass index 23.7±4.0 kg/m², utilizing the gold standard equipment for evaluation of HGS and following all methodological recommendations of the American Society of Hand Therapists (ASTH). The results of the Bland-Altman diagram for the dominant hand (DH) had a mean error (bias) of -8.4% (95%CI -51.6-34.7). The Bland-Altman diagram for the non-dominant hand (NDH) had a mean error (bias) of 1.4% (95%CI -47.1-49.8). The calculation of Cronbach's alpha was 0.69 for the DH and 0.59 for the NDH. The intraclass correlation coefficient was 0.52 (95%CI 31-68) for the DH and 0.42 (95%CI 20-60) for the NDH. We therefore conclude that the reference equations for HGS evaluated in this study has low predictive validity for a population of Brazilian men middle-aged and elderly, and may lead to a misinterpretation of the results.

Citation

ID: 258758
Ref Key: fernandes2012fisioterapiavalidade
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
258758
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet