safety and efficacy of epicardial approach to catheter ablation of ventricular tachycardia – an institutional experience

safety and efficacy of epicardial approach to catheter ablation of ventricular tachycardia – an institutional experience

;Jayapandian Pandian;Daljeet Kaur;Sachin Yalagudri;Soumen Devidutta;Gomathi Sundar;Sridevi Chennapragada;Calambur Narasimhan
renewable energy 2017 Vol. 69 pp. 170-175
186
pandian2017indiansafety

Abstract

Background and aim: Epicardial approach to VT ablation increases the success rate of ablation but is not without complications. We studied the safety and efficacy of epicardial VT ablations performed at our institute. Methods: All patients who underwent epicardial VT ablation at our institute were studied retrospectively. The outcome of VT ablation was among three groups: ischaemic cardiomyopathy (ICM), non-ischaemic cardiomyopathy (NICM) and granulomatous myocarditis (GM). Safety outcomes assessed included all complications considered to be due to pericardial access or epicardial mapping/ablation. Results: A total of 54 patients (total 119 VTs, mean 2.2 (0.9)) were taken up for ablation procedure through epicardial access. Mean age: 47 (10) years, males: 83%. All patients had drug resistant recurrent VTs. The epicardial procedure was abandoned in three patients due to access issues; percutaneous sub-xiphoid access was employed in 48 and surgical approach in four patients. Complete success was achieved in 59% and partial success in 76%. The outcomes were poor in ICM patients as compared to those with GM and NICM. Overall success rates for all clinical VTs were 89% in GM, 90% in NICM and 67% in ICM. Success rates for epicardial VT ablation were 94%, 85% and 78% respectively for GM, NICM and ICM. Procedure related complications occurred in six patients. Conclusion: Epicardial ablation for VT offers good immediate outcomes with acceptable safety profile.

Citation

ID: 257841
Ref Key: pandian2017indiansafety
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
257841
Unique Identifier:
10.1016/j.ihj.2016.10.010
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet