the effect of positive end-expiratory pressure during anesthesia on arterial oxygen saturation after surgery in patient undergoing cesarean section

the effect of positive end-expiratory pressure during anesthesia on arterial oxygen saturation after surgery in patient undergoing cesarean section

;Mahmood Ganjifard;Masoumeh Samii;Samaneh Kouzegaran;Amir Sabertanha
journal of applied mathematics 2018 Vol. 28 pp. -
224
ganjifard2018europeanthe

Abstract

One of the major complications of general anesthesia in the recovery room is arterial oxygen desaturation and hypoxemia. Positive end-expiratory pressure (PEEP) can improve arterial oxygen saturation by increasing FRC. This study aims to evaluate the effects of applying PEEP on arterial oxygen saturation and hemodynamic parameters in the patient undergoing cesarean section in VALIASR hospital. In this double blind clinical trial we randomly allocated 120 patients of class1 and 2 ASA scheduled to undergoing cesarean section into 3 group (in 40).Different levels of PEEP (0, 5 and 10 CmH2o) were applied to each group while zero PEEP was established as control. All other variables (anesthesia and surgery techniques) were the same for all patients SPO2, noninvasive mean arterial pressure and heart rate were measured before, during and after surgery (Recovery room). The comparison of noninvasive arterial blood pressure and heart rate during and after surgery did not show significant differences but mean o2 saturation in group B (5 cmH2o PEEP) and C (10 cm H2o PEEP) in PACU was higher than control group (98.30±0.93 and 98.50±0.90 as opposed to97.12±1.15 respectively) P0<001. In light of results applying PEEP is effective in preventing desaturation after surgery and improving respiratory indexes without the significant hemodynamic changes, the result of using five cmH2o PEEP is more efficient and satisfying.

Citation

ID: 256496
Ref Key: ganjifard2018europeanthe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
256496
Unique Identifier:
10.4081/ejtm.2018.7191
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet