comparison of the laryngeal view during tracheal intubation using airtraq and macintosh laryngoscopes by unskillful anesthesiology residents: a clinical study

comparison of the laryngeal view during tracheal intubation using airtraq and macintosh laryngoscopes by unskillful anesthesiology residents: a clinical study

;Carlos Ferrando;Gerardo Aguilar;F. Javier Belda
journal of dinamika hukum 2011 Vol. 2011 pp. -
342
ferrando2011anesthesiologycomparison

Abstract

Background and Objective. The Airtraq laryngoscope (Prodol Meditec, Vizcaya, Spain) is a novel tracheal intubation device. Studies, performed until now, have compared the Airtraq with the Macintosh laryngoscope, concluding that it reduces the intubation times and increase the success rate at first intubation attempt, decreasing the Cormack-Lehane score. The aim of the study was to evaluate if, in unskillful anesthesiology residents during the laryngoscopy, the Airtraq compared with the Macintosh laryngoscope improves the laryngeal view, decreasing the Cormack-Lehane score. Methods. A prospective, randomized, crossed-over trial was carried out on 60 patients. Each one of the patients were intubated using both devices by unskillful (less than two hundred intubations with the Macintosh laryngoscope and 10 intubations using the Airtraq) anesthesiology residents. The Cormack-Lehane score, the success rate at first intubation attempt, and the laryngoscopy and intubation times were compared. Results. The Airtraq significantly decreased the Cormack-Lehane score (𝑃=0.04). On the other hand, there were no differences in times of laryngoscopy (𝑃=0.645; IC 95% 3.1, +4.8) and intubation (𝑃=0.62; C95%  −6.1, +10.0) between the two devices. No relevant complications were found during the maneuvers of intubation using both devices. Conclusions. The Airtraq is a useful laryngoscope in unskillful anesthesiology residents improving the laryngeal view and, therefore, facilitating the tracheal intubation.

Citation

ID: 253738
Ref Key: ferrando2011anesthesiologycomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
253738
Unique Identifier:
10.1155/2011/301057
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet