determination of dosimetric parameters of the second model of pd-103 seed manufactured at agricultural, medical and industrial research school

determination of dosimetric parameters of the second model of pd-103 seed manufactured at agricultural, medical and industrial research school

;Gholamreza Raisali;Mahdi Sadeghi;Vahideh Ataeinia;Arjang Shahvar;Maryam Ghasemi Ghonchehnazi
the international archives of the photogrammetry, remote sensing and spatial information sciences 2008 Vol. 5 pp. 9-22
166
raisali2008iraniandetermination

Abstract

Introduction: The use of low energy isotopes such as  103 Pd in brachytherapy for the treatment of cancers  such as prostate, eye, head, neck, breast and cervix is increasing. In this regard, different models of Pd- 103  seeds  have  been  designed  and  manufactured  at  the  Agricultural,  Medical  and  Industrial  Research  School (AMIRS) of Atomic Energy Organization of Iran. In this research, the dosimetric parameters of  the second model of Pd-103 seed manufactured at AMIRS have been calculated and measured.   Materials and Methods: The dosimetric parameters of the second Pd-103 seed manufactured at AMIRS  were determined according to TG-43U1 protocol using Monte Carlo calculations (MCNP4C computer  code)  and  measurements  performed  using  TLD-GR200A  dosimeters  in  a  Perspex  phantom.  The  parameters  include  dose  rate  constant,  geometry  function,  radial  dose  function,  anisotropy  function,  anisotropy factor and anisotropy constant.  Results:  It  was  found  that  by  using  MCNP4C  code  the  calculated  dose  rate  constant  in  water  and  Perspex  was  0.706±0.001   and  0.501±0.001  cGyh -1 U -1 , respectively.  Using  the  calculated  geometry  function,  the  radial  dose  function  and  the  anisotropy  function  were  determined  by  experimental  and  theoretical methods in water and Perspex phantom. Also, the calculated value of anisotropy constant in  water was equal to 0.88.  Discussion and Conclusion: A discrepancy of less than 10% between the calculated and the measured  values indicates a reasonable agreement between the simulation and the measurement method. Also, the  dosimetric parameters of this seed have been compared to the dosimetric parameters of the first Pd-103  seed  manufactured  at  AMIRS  and  some  other  seeds.  The  obtained  results  indicate  that  the  seeds  manufactured at AMIRS have acceptable dosimetric parameters suitable for brachytherapy applications.

Citation

ID: 250906
Ref Key: raisali2008iraniandetermination
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
250906
Unique Identifier:
10.22038/ijmp.2008.7526
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet