computational fem model, phantom and ex vivo swine breast validation of an optimized double-slot microcoaxial antenna designed for minimally invasive breast tumor ablation: theoretical and experimental comparison of temperature, size of lesion, and swr, preliminary data

computational fem model, phantom and ex vivo swine breast validation of an optimized double-slot microcoaxial antenna designed for minimally invasive breast tumor ablation: theoretical and experimental comparison of temperature, size of lesion, and swr, preliminary data

;Geshel David Guerrero López;Mario Francisco Jesús Cepeda Rubio;José Irving Hernández Jácquez;Arturo Vera Hernandez;Lorenzo Leija Salas;Francisco Valdés Perezgasga;Francisco Flores García
advanced functional materials 2017 Vol. 2017 pp. -
129
lpez2017computationalcomputational

Abstract

Malignant neoplasms are one of the principal world health concerns and breast cancer is the most common type of cancer in women. Advances in cancer detection technologies allow treating it in early stages; however, it is necessary to develop treatments which carry fewer complications and aesthetic repercussions. This work presents a feasibility study for the use of microwave ablation as a novel technique for breast cancer treatment. A microwave applicator design is also being proposed for this purpose. The coupling of the designed antenna was predicted with computer simulation. The standing wave ratio obtained through simulation was 1.87 and the result of experimental validation was 1.04. The optimized antenna has an optimal coupling (SWR = 1.04) so ablation temperatures can be achieved in a relatively short time using low power. Varying the time and power, the heating pattern can be changed to treat different tumors. However, as some discrepancies are still present, a deeper study of the dielectric properties and their variation with temperature is required.

Citation

ID: 245320
Ref Key: lpez2017computationalcomputational
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
245320
Unique Identifier:
10.1155/2017/1562869
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet