functional relationship of room temperature and setting time of alginate impression material

functional relationship of room temperature and setting time of alginate impression material

;Dyah Irnawati;Siti Sunarintyas
industrial crops and products 2009 Vol. 42 pp. 137-140
219
irnawati2009dentalfunctional

Abstract

Background: Indonesia is a tropical country with temperature variation. A lot of dental clinics do not use air conditioner. The room temperature influences water temperature for mixing alginate impression materials. Purpose: The aim of this study was to investigate the functional relationship of room temperature and initial setting time of alginate impression materials. Methods: The New Kromopan® alginate (normal and fast sets) were used. The initial setting time were tested at 23 (control), 24, 25, 26, 27, 28, 29, 30 and 31 degrees Celcius room temperatures (n = 5). The initial setting time was tested based on ANSI/ADA Specification no. 18 (ISO 1563). The alginate powder was mixed with distilled water (23/50 ratio), put in the metal ring mould, and the initial setting time was measured by test rod. Data were statistically analyzed by linear regression (α = 0.05). result: The initial setting times were 149.60 ± 0.55 (control) and 96.40 ± 0.89 (31° C) seconds for normal set, and 122.00 ± 1.00 (control) and 69.60 ± 0.55 (31° C) seconds for fast set. The coefficient of determination of room temperature to initial setting time of alginate were R2 = 0.74 (normal set) and R2 = 0.88 (fast set). The regression equation for normal set was Y = 257.6 – 5.5 X (p < 0.01) and fast set was Y = 237.7 – 5.6 X (p < 0.01). Conclusions: The room temperature gave high contribution and became a strength predictor for initial setting time of alginates. The share contribution to the setting time was 0.74% for normal set and 0.88% for fast set alginates.

Citation

ID: 243624
Ref Key: irnawati2009dentalfunctional
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
243624
Unique Identifier:
10.20473/j.djmkg.v42.i3.p137-140
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet