validation of mipas imk/iaa v5r_o3_224 ozone profiles

validation of mipas imk/iaa v5r_o3_224 ozone profiles

;A. Laeng;U. Grabowski;T. von Clarmann;G. Stiller;N. Glatthor;M. Höpfner;S. Kellmann;M. Kiefer;A. Linden;S. Lossow;V. Sofieva;I. Petropavlovskikh;D. Hubert;T. Bathgate;P. Bernath;C. D. Boone;C. Clerbaux;P. Coheur;R. Damadeo;D. Degenstein;S. Frith;L. Froidevaux;J. Gille;K. Hoppel;M. McHugh;Y. Kasai;J. Lumpe;N. Rahpoe;G. Toon;T. Sano;M. Suzuki;J. Tamminen;J. Urban;J. Urban;K. Walker;M. Weber;J. Zawodny
bioorganic & medicinal chemistry 2014 Vol. 7 pp. 3971-3987
67
laeng2014atmosphericvalidation

Abstract

We present the results of an extensive validation program of the most recent version of ozone vertical profiles retrieved with the IMK/IAA (Institute for Meteorology and Climate Research/Instituto de Astrofísica de Andalucía) MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) research level 2 processor from version 5 spectral level 1 data. The time period covered corresponds to the reduced spectral resolution period of the MIPAS instrument, i.e., January 2005–April 2012. The comparison with satellite instruments includes all post-2005 satellite limb and occultation sensors that have measured the vertical profiles of tropospheric and stratospheric ozone: ACE-FTS, GOMOS, HALOE, HIRDLS, MLS, OSIRIS, POAM, SAGE II, SCIAMACHY, SMILES, and SMR. In addition, balloon-borne MkIV solar occultation measurements and ground-based Umkehr measurements have been included, as well as two nadir sensors: IASI and SBUV. For each reference data set, bias determination and precision assessment are performed. Better agreement with reference instruments than for the previous data version, V5R_O3_220 (Laeng et al., 2014), is found: the known high bias around the ozone vmr (volume mixing ratio) peak is significantly reduced and the vertical resolution at 35 km has been improved. The agreement with limb and solar occultation reference instruments that have a known small bias vs. ozonesondes is within 7% in the lower and middle stratosphere and 5% in the upper troposphere. Around the ozone vmr peak, the agreement with most of the satellite reference instruments is within 5%; this bias is as low as 3% for ACE-FTS, MLS, OSIRIS, POAM and SBUV.

Citation

ID: 239792
Ref Key: laeng2014atmosphericvalidation
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
239792
Unique Identifier:
10.5194/amt-7-3971-2014
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet