Abstract
The subject matter of the article represents summarized findings of the variance analysis of the
fractional factorial experiment (the Latin Matrix). The items analyzed collectively by the coauthors
include the discharge current, the pressure of the orifice gas, or the air, and the period of exposure to
the direct current of the glow discharge. The properties analyzed by the coauthors include the water
absorption capacity, the wettability, and the capillary rise of the repair vlieseline. The discharge current
range was 20-100 mA, the pressure range was 50-200 Pa and the treatment time range was
15-120. The experiment was conducted according to the Latin matrix method, and the analysis of
variance (ANOVA) was used to check the influence of the discharge current, pressure and the treatment
time onto the hydrophilic properties of the material. The coauthors have demonstrated that the
discharge parameters are an insignificant factor in comparison to the exposure period.
Citation
ID:
235711
Ref Key:
viktorovich2012vestnikvariance