factors related to the effectiveness of variable stiffness colonoscope: results of a multivariate analysis

factors related to the effectiveness of variable stiffness colonoscope: results of a multivariate analysis

;Javier Sola-Vera;Francisco Uceda;Alicia Brotons;Jesús Sáez;Eva Girona;Estefanía Pérez;María Dolores Picó;Concepción Grau;Narciso Vázquez
chemistry of heterocyclic compounds 2014 Vol. 106 pp. 15-21
161
sola-vera2014revistafactors

Abstract

Background: Various studies and two meta-analysis have shown that a variable stiffness colonoscope improves cecal intubation rate. However, there are few studies on how this colonoscope should be used. Objective: The aim of this study was to identify factors related to the advancement of the colonoscope when the variable stiffness function is activated. Methods: Prospective study enrolling consecutive patients referred for colonoscopy. The variable stiffness colonoscope (Olympus CF-H180DI/L®) was used. We performed univariate and multivariate analyses of factors associated with the success of the variable stiffness function. Results: After the data inclusion period, 260 patients were analyzed. The variable stiffness function was used most in the proximal colon segments (ascending and transverse colon 85 %; descending/sigmoid colon 15.2 %). The body mass index was lower in patients in whom the endoscope advanced after activating the variable stiffness than those in which it could not be advanced (25.9 ± 4.8 vs. 28.3 ± 5.4 kg/m², p = 0.009). The endoscope advanced less frequently when the stiffness function was activated in the ascending colon versus activation in other segments of the colon (25 % vs. 64.5 % ascending colon vs. other segments; p < 0.05). In the multivariate analysis, only the colon segment in which the variable stiffness was activated was an independent predictor of advancement of the colonoscope. Conclusions: The variable stiffness function is effective, allowing the colonoscope advancement especially when applied in the transverse colon, descending colon and sigmoid. However, when used in the ascending colon it has a lower effectiveness.

Citation

ID: 235177
Ref Key: sola-vera2014revistafactors
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
235177
Unique Identifier:
10.4321/s1130-01082014000100003
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet