comparison of fecal calprotectin methods for predicting relapse of pediatric inflammatory bowel disease

comparison of fecal calprotectin methods for predicting relapse of pediatric inflammatory bowel disease

;Saranya Kittanakom;Md. Sharif Shajib;Kristine Garvie;Joceline Turner;Dan Brooks;Sufian Odeh;Robert Issenman;V. Tony Chetty;Joseph Macri;Waliul I. Khan
Journal of food science and technology 2017 Vol. 2017 pp. -
86
kittanakom2017canadiancomparison

Abstract

Background. Pediatric inflammatory bowel disease (IBD) is on the rise worldwide. Endoscopies are necessary for IBD assessment but are invasive, expensive, and inconvenient. Recently, fecal calprotectin (FCal) was proposed as a noninvasive and specific marker of gut inflammation. We evaluated the analytical performance of three FCal assays and their clinical performance in predicting relapse in pediatric IBD. Methods. This study used 40 pediatric IBD and 40 random non-IBD patients’ fecal samples. Two automated ELISAs (Bühlmann and PhiCal® Calprotectin-EIA) and an EliA (Phadia 250 EliA-Calprotectin) were used to evaluate the analytical performance. The clinical performance was assessed by PhiCal Calprotectin-EIA, EliA-Calprotectin, and Bühlmann immunochromatographic point-of-care test (POCT). Results. All assays displayed acceptable analytical performance below and above the medical decision cut-off [imprecision (CV < 10% intra-assay; <15% interassay); linearity (overall mean % deviation < 16.5%)]. The agreement with PhiCal Calprotectin-EIA was 100% and 78.6% for Bühlmann (95% CI, 87.5–100; Kappa: 1) and EliA-Calprotectin (95% CI, 60.5–89.8; Kappa: 0.32), respectively, and 63.6% between Bühlmann and EliA-Calprotectin (95% CI, 46.6–77.8; Kappa: 0.16). All assays evaluated had similar clinical performance [AUC: 0.84 (EliA-Calprotectin); 0.83 (POCT and PhiCal Calprotectin-EIA)]. Conclusion. FCal levels determined using the same method and assay together with clinical history would be a noninvasive and useful tool in monitoring pediatric IBD.

Citation

ID: 227795
Ref Key: kittanakom2017canadiancomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
227795
Unique Identifier:
10.1155/2017/1450970
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet