Plasma levels of soluble membrane attack complex are elevated despite viral suppression in HIV patients with poor immune reconstitution.

Plasma levels of soluble membrane attack complex are elevated despite viral suppression in HIV patients with poor immune reconstitution.

Schein, Theresa N;Blackburn, Tessa E;Heath, Sonya L;Barnum, Scott R;
clinical and experimental immunology 2019
269
schein2019plasmaclinical

Abstract

The complement system is now a therapeutic target for the management of serious and life-threatening conditions such as paroxysmal nocturnal hemoglobinuria, atypical hemolytic uremic syndrome, glomerulonephritis and other diseases caused by complement deficiencies or genetic variants. As complement therapeutics expand into more clinical conditions, monitoring complement activation is increasingly important, as is the baseline levels of complement activation fragments in blood or other body fluid levels. Although baseline complement levels have been reported in the literature, the majority of this data was generated using non-standard assays and with variable sample handling, potentially skewing results. In this study, we examined the plasma and serum levels of the soluble membrane attack complex of complement (sMAC). sMAC is formed in the fluid phase when complement is activated through the terminal pathway. It binds the regulatory proteins vitronectin and/or clusterin and cannot insert into cell membranes, and can serve as a soluble diagnostic marker in infectious disease settings, as previously shown for intraventricular shunt infections. Here we show that in healthy adults, serum sMAC levels were significantly higher than those in plasma, that plasma sMAC levels were similar between in African-Americans than Caucasians, and that plasma sMAC levels increase with age. Plasma sMAC levels were significantly higher in virally suppressed people living with HIV (PLWH) compared to non-HIV infected healthy donors. More specifically, PLWH with CD4+T cell counts below 200 had even greater sMAC levels, suggesting diagnostic value in monitoring sMAC levels in this group. This article is protected by copyright. All rights reserved.

Citation

ID: 22711
Ref Key: schein2019plasmaclinical
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
22711
Unique Identifier:
10.1111/cei.13366
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet