Catheter Dwell Time and Risk of Catheter Failure in Adult Patients with Peripheral Venous Catheters.

Catheter Dwell Time and Risk of Catheter Failure in Adult Patients with Peripheral Venous Catheters.

Wei, Tao;Li, Xu-Ying;Yue, Zhi-Ping;Chen, Yong-Yi;Wang, Yi-Ren;Yuan, Zhong;Lin, Qin;Tan, Yan;Peng, Si-Yi;Li, Xing-Feng;
Journal of clinical nursing 2019
209
wei2019catheterjournal

Abstract

To explore whether the risk of peripheral venous catheters failure remained constant throughout catheter use in adult patients.Peripheral venous catheters, widely used in adult patients, may have a critical threshold dwell time associated with increased risk of catheter failure.Prospective, observational study. We have complied with the STROBE Checklist of items.This study was conducted from July to October 2018 in Hunan, China. Data on patient factors, catheter factors, and catheter failure events were collected. Poisson regression was used to assess the effect of catheter dwell time on catheter failure while adjusting for other variables.A total of 1477 patients were included in the analysis. There were 854 cases (57.8%) of catheter failure. The median dwell time to catheter failure was 52 h (interquartile range: 36-73 h). The incidence rate of catheter failure significantly increased by 1.1%/h in the first 38 h after catheter insertion. From 39-149 h, the incidence rate significantly decreased, and at >149 h, there was no significant change in the incidence rate. Meanwhile, factors like vascular quality and infused drugs showed having an impact on catheter failure events.The risk of catheter failure may not remain constant throughout the dwell time. The results suggest that nurses should assess the insertion site frequently in the first 38 h.The significant increase in the risk of catheter failure per hour may warrant close and frequent inspection of insertion site during the first 38 hours.

Citation

ID: 22694
Ref Key: wei2019catheterjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
22694
Unique Identifier:
10.1111/jocn.15035
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet