A Modified Design of a Thermocouple Based Digital Temperature Indicator with Opto-Isolation
BERA, S. C.;KOLE, D. N.;
sensors & transducers2008Vol. 87pp. 24-30
172
bera2008asensors
Abstract
In the conventional thermocouple based digital temperature indicator the millivolt signal obtained from a thermocouple is first amplified and then converted into a digital signal by using analog-to-digital converter (ADC). This digital signal is then indicated as digital display of temperature using digital counter circuit or microprocessor/microcontroller based circuitry. In the present paper a modified AD conversion technique along with opto-isolation is used to indicate digitally the temperature without using any conventional analog-to-digital converter. The theory and design of the measuring technique are described in the paper. The non-linearity of thermocouple is eliminated by using look-up table within software program. The performance of the circuit has been experimentally tested by using mV input signal instead of a thermocouple as well as using a K-type thermocouple. The experimental results are reported in the paper.