evaluation of low versus high volume per minute displacement co2 methods of euthanasia in the induction and duration of panic-associated behavior and physiology

evaluation of low versus high volume per minute displacement co2 methods of euthanasia in the induction and duration of panic-associated behavior and physiology

;Debra L. Hickman;Stephanie D. Fitz;Cristian S. Bernabe;Izabela F. Caliman;Melissa M. Haulcomb;Lauren M. Federici;Anantha Shekhar;Philip L. Johnson
translational oncology 2016 Vol. 6 pp. 45-
166
hickman2016animalsevaluation

Abstract

Current recommendations for the use of CO 2 as a euthanasia agent for rats require the use of gradual fill protocols (such as 10% to 30% volume displacement per minute) in order to render the animal insensible prior to exposure to levels of CO 2 that are associated with pain. However, exposing rats to CO 2 , concentrations as low as 7% CO 2 are reported to cause distress and 10%–20% CO 2 induces panic-associated behavior and physiology, but loss of consciousness does not occur until CO 2 concentrations are at least 40%. This suggests that the use of the currently recommended low flow volume per minute displacement rates create a situation where rats are exposed to concentrations of CO 2 that induce anxiety, panic, and distress for prolonged periods of time. This study first characterized the response of male rats exposed to normoxic 20% CO 2 for a prolonged period of time as compared to room air controls. It demonstrated that rats exposed to this experimental condition displayed clinical signs consistent with significantly increased panic-associated behavior and physiology during CO 2 exposure. When atmospheric air was then again delivered, there was a robust increase in respiration rate that coincided with rats moving to the air intake. The rats exposed to CO 2 also displayed behaviors consistent with increased anxiety in the behavioral testing that followed the exposure. Next, this study assessed the behavioral and physiologic responses of rats that were euthanized with 100% CO 2 infused at 10%, 30%, or 100% volume per minute displacement rates. Analysis of the concentrations of CO 2 and oxygen in the euthanasia chamber and the behavioral responses of the rats suggest that the use of the very low flow volume per minute displacement rate (10%) may prolong the duration of panicogenic ranges of ambient CO 2 , while the use of the higher flow volume per minute displacement rate (100%) increases agitation. Therefore, of the volume displacement per minute rates evaluated, this study suggests that 30% minimizes the potential pain and distress experienced by the animal.

Citation

ID: 222987
Ref Key: hickman2016animalsevaluation
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
222987
Unique Identifier:
10.3390/ani6080045
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet