internal carotid artery stenosis: comparison of duplex scan and magnetic resonance angiography with digital subtraction angiography

internal carotid artery stenosis: comparison of duplex scan and magnetic resonance angiography with digital subtraction angiography

;Py Marco Oliveira;André Charles;Azevedo Feliciano Silva de;Domingues Romeu Côrtes;Salomão Rodrigo Ferraz
communications in computer and information science 2001 Vol. 59 pp. 665-671
189
oliveira2001arquivosinternal

Abstract

OBJECTIVE: We compare duplex scan (DS) and magnetic resonance angiography (MRA) with digital angiography (DGA) in respect to accuracy in measuring internal carotid artery (IC) stenosis in symptomatic patients. METHOD: Ten symptomatic patients with IC stenosis greater than 70% previously diagnosed by DS were submitted to another DS and to both MRA and DGA. Both ICs from each patient (total 20 ICs) were evaluated by physicians blinded for the results of other tests. DS and MRA were compared with DGA, using the intraclass correlation coeficient (r) and its 95% confidence interval (95% ci). For each diagnostic test, the study group (20 Ics) was also divided in surgical patients (IC stenosis between 70 and 99%) and non surgical patients, using kappa concordance coeficient (k) to compare the results. RESULTS: Main comparisons are: DS and DGA, r = 0.71 (0.4 - 0.87); MRA and DGA, r = 0.61 (0.25 - 0.82). After division into surgical vs. non-surgical groups, k = 0.857 (p < 0.0001) between DS and DGA; and k = 0.545 (p = 0.003) between MRA and DGA. Most DS and MRA errors occurred in IC sub-occlusions. CONCLUSION: The results suggest that when they are used together, DS and non-contrast MRA may substitute DGA in the evaluation of patients for IC stenosis surgery, except when there is discordance between their results or when the methods show sub-occlusive stenosis.

Citation

ID: 213659
Ref Key: oliveira2001arquivosinternal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
213659
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet