assessment of a modification of brückner′s test as a screening modality for anisometropia and strabismus

assessment of a modification of brückner′s test as a screening modality for anisometropia and strabismus

;Abadan Khan Amitava;D Kewlani;Z Khan;A Razzak
BMJ 2010 Vol. 3 pp. 131-135
184
amitava2010omanassessment

Abstract

Background : Current amblyopia screening methods are not cost effective. Aim : To evaluate the diagnostic capability of a modified Brückner test (MBT) for amblyopiogenic risk factors. Materials and Methods : We applied the MBT using the streak retinoscope to identify anisometropia and strabismus by noting an inter-ocular difference in movement and glow, from children who failed 6/9 Snellen on community vision screening, followed by comprehensive eye examination. Statisitics : Data were analyzed by 2 Χ 2 tables for diagnostic test parameters (95% CI). Results : From 7998 children vision-screened, 392 failed 6/9 VA and were referred. Since 34 failed to reach the centers, and 15 were excluded due to poor/ no glow, data from 343 was analyzed. The prevalence of anisometropia of 0.5D was 17%, of 1D was 11% and of strabismus 5%. For the MBT the accuracy was ≥ 90% (95%CI 89% to 97%) over the three outcomes. The sensitivity, specificity, NPV and +LR for anisometropia of 0.5D were: 0.57 (0.48, 0.64), 0.97 (0.95, 0.98), 0.92 (0.90, 0.93) and 18 (9.7, 35); for 1D: 0.74(0.60, 0.82), 0.95 (0.94, 0.97), 0.97 (0.95, 0.98) and 16 (9.3, 28); and for strabismus: 0.5 (0.32, 0.66), 0.98 (0.97, 0.98), 0.97 (0.96, 0.98) and 20 (9.1, 42). Conclusion : Our data suggests that the MBT is highly accurate and useful for ruling in anisometropia and strabismus in children who fail 6/9 Snellen. The MBT needs further validation, both by different care givers and on differing populations. It offers an affordable, portable, and clinically useful tool to detect anisometropia and strabismus. We suggest that performing an MBT prior to uniocular retinosocpy should be a routine practice.

Citation

ID: 207696
Ref Key: amitava2010omanassessment
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
207696
Unique Identifier:
10.4103/0974-620X.71890
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet