Volume Guaranteed Ventilation During Neonatal Transport.

Volume Guaranteed Ventilation During Neonatal Transport.

Belteki, Gusztav;Szell, Andras;Lantos, Lajos;Kovacs, Gabor;Szanto, Gyula;Berenyi, Aniko;Szilagyi, Monika;Liszkay, Gabor;Kohalmi, Ferenc;Morley, Colin;Somogyvari, Zsolt;
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies 2019
224
belteki2019volumepediatric

Abstract

To compare tidal volumes, inflating pressures and other ventilator variables of infants receiving synchronized intermitted mandatory ventilation with volume guarantee during emergency neonatal transport with those of infants receiving synchronized intermitted mandatory ventilation without volume guarantee.Retrospective observational study.A regional neonatal emergency transport service.We enrolled 77 infants undergoing emergency neonatal transfer. Forty-five infants were ventilated with synchronized intermittent mandatory ventilation with volume guarantee and 32 with synchronized intermitted mandatory ventilation without volume guarantee.Infants received synchronized intermitted mandatory ventilation with or without volume guarantee during interhospital emergency neonatal transport using a Fabian + nCPAP evolution neonatal ventilator (Software Version: 4.0.1; Acutronic Medical Instruments, Hirzel, Switzerland).We downloaded detailed ventilator data with 0.5 Hz sampling rate. We analyzed data with the Python computer language and its data science packages. The mean expiratory tidal volume of inflations was lower and less variable in infants ventilated with volume guarantee than in babies ventilated without volume guarantee (group median 4.8 vs 6.0 mL/kg; p = 0.001). Babies ventilated with synchronized intermittent mandatory ventilation with volume guarantee had on average lower and more variable peak inflating pressures than babies ventilated without volume guarantee (group median 15.5 vs 19.5 cm H2O;p = 0.0004). With volume guarantee, a lower proportion of the total minute ventilation was attributed to ventilator inflations rather than to spontaneous breaths between inflations (group median 66% vs 83%; p = 0.02). With volume guarantee, babies had fewer inflations with tidal volumes greater than 6 mL/kg and greater than 8 mL/kg (group medians 3% vs 44% and 0% vs 7%, respectively; p = 0.0001). The larger tidal volumes in the non-volume guarantee group were not associated with significant hypocapnia except in one case.During neonatal transport, synchronized intermittent mandatory ventilation with volume guarantee ventilation reduced the occurrence of excessive tidal volumes, but it was associated with larger contribution of spontaneous breaths to minute ventilation compared with synchronized intermitted mandatory ventilation without volume guarantee.

Citation

ID: 20266
Ref Key: belteki2019volumepediatric
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
20266
Unique Identifier:
10.1097/PCC.0000000000002090
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet