comparison of two analytical platforms for csf biomarkers of alzheimer’s disease

comparison of two analytical platforms for csf biomarkers of alzheimer’s disease

;Jose Antonio Monge-Argilés;Carlos Muñoz-Ruiz;José Sánchez-Payá;Ruth Gasparini Berenguer;Maria Empar Blanco Cantó;Carlos Leiva-Santana
spectrochimica acta - part a: molecular and biomolecular spectroscopy 2014 Vol. 2014 pp. -
141
monge-argils2014biomedcomparison

Abstract

Cerebrospinal fluid (CSF) biomarkers of Alzheimer’s disease (AD) are currently being assessed with two different assays. Our objective was to study if there is a correlation between values obtained by both techniques, to compare their validity and search for conversion factor between values obtained for every protein. We compared the performances of two commonly used platforms, an enzyme-linked immunosorbent assay (ELISA) and a multiplex (xMAP) technology for measurement of CSF Aβ1–42, total tau (T-tau), and phosphorylated tau 181 (P-tau181p) proteins, in 30 AD patients and 28 control subjects. The relations between the variables of both techniques were evaluated using the Spearman p correlation coefficient (α=0.05). Receiver operating characteristic and area under the curve (AUC) analyses were calculated for the variables of both techniques. The two assays platforms yielded different absolute values for the various analytes, always higher in ELISA. We found some correction factor between values: 2,1- to 3-fold for Aβ1–42; 4,1- to 4,6-fold for T-tau; and 1,4- to 1,6-fold for P-tau181p. In addition, those values were highly correlated (Aβ1–42: r=0.70, P<0.01; T-tau: r=0.90, P<0.01; P-tau181p: r=0.85, P<0.01) and the AUC for the variables showed very similar values. In conclusion, the results obtained with ELISA and xMAP platforms were highly correlated and its validity is very similar. Differences in absolute values point to the need for a clear description of the technique used. Moreover, we found some conversion factor between values of every protein that may be useful for transformation between both techniques.

Keywords

Citation

ID: 192611
Ref Key: monge-argils2014biomedcomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
192611
Unique Identifier:
10.1155/2014/765130
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet