prueba de caminata de carga progresiva (shuttle test) en enfermedad pulmonar obstructiva crónica grave shuttle test in severe copd patients

prueba de caminata de carga progresiva (shuttle test) en enfermedad pulmonar obstructiva crónica grave shuttle test in severe copd patients

;Martín Sívori;César Sáenz
proceedings on: 2016 ieee central america and panama student conference, conescapan 2016 2010 Vol. 70 pp. 305-310
180
svori2010medicinaprueba

Abstract

La prueba de caminata de carga progresiva (shuttle test, PCCP) tiene escaso uso en nuestro país. Este estudio comparó diferentes variables de la PCCP con la de caminata de 6 minutos (PC6M) y el consumo de oxígeno (VO2max) en enfermedad pulmonar obstructiva crónica (EPOC) grave. A 21 pacientes con EPOC grave estable (estadios GOLD III-IV), se les realizó PC6M, PCCP, y VO2max. Se evaluaron frecuencia cardíaca, saturación de oxígeno y escala de disnea (Borg). Se realizaron espirometría, gases en sangre y cuestionario de calidad de vida (CRQ). Se utilizaron prueba t de Student para datos apareados y coeficiente de correlación de Pearson (significación < 0.05). La media de edad fue 65.27 ± 12.72 años y la obstrucción al flujo aéreo fue grave, (FEV1: 33.23 ± 4.94%). La respuesta al ejercicio para PC6M 297.85 ± 173.24 metros; PCCP: 318.8 ± 42.42 metros y VO2max 14.7 ± 5.44 ml/kg/min. El coeficiente de correlación del metraje caminado entre PC6M y PCCP fue r: 0.52 (p = 0.00085); entre PCCP y VO2max (l/min): r: 0.78 (p = 0.00079), y PCCP y VO2max (ml/kg/min): r: 0.81 (p = 0.00065). Se observó correlación moderada en la frecuencia cardíaca final (r: 0.41, p = 0.00091), escala de disnea máxima (r: 0.47, p = 0.00099), y alta en la saturación de oxígeno final (r: 0.81, p = 0.00087) entre PCCP y VO2max. No hubo correlación entre PCCP y FEV1 entre PCCP y calidad de vida. En conclusión, la PCCP como prueba de ejercicio de campo máxima es sencilla y de bajo costo, su correlación con la prueba de VO2max es alta, constituyendo una herramienta útil en lugares donde no existe disponibilidad de aparatos más costosos.
The shuttle test (ST) is a maximal exercise field test with scarcely used in Argentina. Our objective was to compare different variables of exercise response to ST vs. other exercise tests such as six minute walking test (SMWT) and cardiopulmonary with maximal oxygen consumption (VO2max) in severe COPD patients. A total of 21 stable severe COPD patients (GOLD III and IV stages) were evaluated with SMWT, ST and VO2max test. In all patients spirometry was performed with bronchodilator response, arterial gas and chronic respiratory questionnaire to evaluate quality of life. Cardiac frequency, oxygen saturation and dyspnea scale by Borg in response to exercise tests were evaluated. Paired T Student and Pearson tests were used, defining p < 0.05 as significant. COPD patients were 65.27 ± 12.72 years old and had severe airflow obstruction (FEV1: 33.23 ± 4.94%). The exercise response to SMWT was 297.85 ± 173.24 meters; ST: 318.8 ± 42.42 meters and VO2max test: 14.7 ± 5.44 ml/kg/min. The correlation between SMWT and ST was: r: 0.52(p < 0.00085); between ST and VO2max (l/min): r: 0.78 (p < 0.00079), and ST and VO2max (ml/kg/min): r: 0.81 (p < 0.00065). Moderate correlation was observed in final heart rate (r: 0.41, p < 0.00091), maximal Borg dyspnea scale (r: 0.47, p < 0.00099) and high correlation with final oxygen saturation (r: 0.81, p < 0.00087) between ST and VO2max. There was no correlation between ST and FEV1 and ST and quality of life. Our conclusion: the ST is a maximal, simple and low cost test. It has high correlation with cardiopulmonary test with VO2max measurement. It is a useful tool in those laboratories for pulmonary evaluations without possible availability of expensive tests.

Citation

ID: 190980
Ref Key: svori2010medicinaprueba
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
190980
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet