rectal tumour staging with endorectal ultrasound: is there any difference between western and eastern european countries?

rectal tumour staging with endorectal ultrasound: is there any difference between western and eastern european countries?

;Anna Fábián;Renáta Bor;Klaudia Farkas;Anita Bálint;Ágnes Milassin;Mariann Rutka;László Tiszlavicz;Tibor Wittmann;Ferenc Nagy;Tamás Molnár;Zoltán Szepes
colloids and surfaces a: physicochemical and engineering aspects 2016 Vol. 2016 pp. -
213
fbin2016gastroenterologyrectal

Abstract

Background. Rectal tumour management depends highly on locoregional extension. Rectal endoscopic ultrasound (ERUS) is a good alternative to computed tomography and magnetic resonance imaging. However, in Hungary only a small amount of rectal tumours is examined with ERUS. Methods. Our retrospective study (2006–2012) evaluates the diagnostic accuracy of ERUS and compares the results, the first data from Central Europe, with those from Western Europe. The effect of neoadjuvant therapy, rectal probe type, and investigator’s experience were also assessed. Results. 311 of the 647 ERUS assessed locoregional extension. Histological comparison was available in 177 cases: 67 patients underwent surgery alone; 110 received neoadjuvant chemoradiotherapy (CRT); ERUS preceded CRT in 77 and followed it in 33 patients. T-staging was accurate in 72% of primarily operated patients. N-staging was less accurate (62%). CRT impaired staging accuracy (64% and 59% for T- and N-staging). Rigid probes were more accurate (79%). At least 30 examinations are needed to master the technique. Conclusions. The sensitivity of ERUS complies with the literature. ERUS is easy to learn and more accurate in early stages but unnecessary for restaging after CRT. Staging accuracy is similar in Western and Central Europe, although the number of examinations should be increased.

Citation

ID: 189531
Ref Key: fbin2016gastroenterologyrectal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
189531
Unique Identifier:
10.1155/2016/8631381
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet