effectiveness and safety of polygeline in patients with hypovolemia due to trauma

effectiveness and safety of polygeline in patients with hypovolemia due to trauma

;Ajai Singh;Sabir Ali;Rohita Shetty
journal of clinical epidemiology 2017 Vol. 10 pp. 116-120
236
singh2017journaleffectiveness

Abstract

Background: This retrospective study examined the effectiveness and safety of polygeline in adult patients with hypovolemia due to traumatic injury. Materials and Methods: Polygeline was administered after evaluating the amount of blood loss and estimating hematological and biochemical parameters. Changes in vital signs, serum electrolytes, arterial pH, and serum lactate were evaluated. The safety was evaluated by recording the adverse events if any. Results: Sixty patients with the mean age 37.5 ± 11.26 years were included in the study. All patients had blood loss < 20%. The mean total polygeline administered was 1025.0 ± 464.18 ml. Blood transfusion was required in 3.33% of patients. Diastolic, systolic, and mean arterial blood pressure and pulse rate significantly increased after 1 h of polygeline administration (P < 0.0001). There was a trend toward increase in urine output (P = 0.0715) after 1 h. The improvement in vital parameters was consistent at 6, 14, and 18 h after administration of polygeline. Arterial pH significantly increased from 7.2 ± 0.12 to 7.3 ± 0.11 after 1 h of administration (P < 0.0001) and was consistent till 24 h (P = 0.035). Blood lactate decreased after 1 h (P < 0.0001). Changes in laboratory parameters were not clinically significant. After mean duration hospital stay of 10.5 ± 4.63 days all patients were discharged without any clinically significant abnormality or adverse event. Conclusion: Polygeline improved hemodynamic stability in patients with hypovolemia due to traumatic injury. The improvement was seen within 1 h (golden hour) of polygeline administration and maintained consistently. Polygeline can be safely administered to patients with traumatic injury to improve hemodynamic parameters and achieve stability.

Citation

ID: 180976
Ref Key: singh2017journaleffectiveness
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
180976
Unique Identifier:
10.4103/JETS.JETS_120_16
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet