invasive hemodynamic assessment of cardiac output state after mitraclip therapy in nonanaesthetized patients with functional mitral regurgitation

invasive hemodynamic assessment of cardiac output state after mitraclip therapy in nonanaesthetized patients with functional mitral regurgitation

;Frantisek Bednar;Tomas Budesinsky;Hana Linkova;Viktor Kocka
spectrochimica acta - part a: molecular and biomolecular spectroscopy 2016 Vol. 2016 pp. -
147
bednar2016biomedinvasive

Abstract

Background. Surgical correction of mitral regurgitation (MR) can lead to postoperative low cardiac output state. We aimed to assess the acute hemodynamic changes after percutaneous MitraClip therapy (a unique model without influence of factors linked to surgical procedure) in patients with functional MR without the influence of general anaesthesia. Methods. We studied invasive hemodynamic parameters in 23 patients before procedure (conscious, nonsedated patients), during procedure (intubated patients), and the first day after MitraClip implantation (conscious, extubated patients). Results. Mitral valve clipping significantly increased cardiac index (CI) (from 2.0 ± 0.5 to 3.3 ± 0.6 L/min/m2; p<0.01). Conversely, there was significant reduction in the mean pulmonary capillary wedge pressure (PCWP) (from 18.6 ± 5.7 to 10.5 ± 3.8 mmHg; p<0.01), mean pulmonary artery pressure (from 29.8 ± 10.9 to 25.2 ± 10.3 mmHg; p=0.03), and pulmonary vascular resistance index (from 531 ± 359 to 365 ± 193 dyn·s·cm−5/m2; p=0.03). Conclusions. The functional MR therapy with percutaneous MitraClip device results in significant increase in CI (+66%) and concomitant decrease in PCWP (−42%). None of our patients developed low cardiac output state. Our results support the idea that significant part of low cardiac output state after cardiac surgery is due to surgery related factors rather than due to increase in afterload after MR elimination.

Keywords

Citation

ID: 179397
Ref Key: bednar2016biomedinvasive
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
179397
Unique Identifier:
10.1155/2016/6296972
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet