comparison of conventional and standardized bone densitometry around implants in periapical radiographs during a three months period

comparison of conventional and standardized bone densitometry around implants in periapical radiographs during a three months period

;Asieh Zamani Naser;Shahab Etemadi;Mansour Rismanchian;Mahnaz Sheikhi;Mohammadbagher Tavakoli
Mycoses 2011 Vol. 8 pp. 33-38
134
naser2011dentalcomparison

Abstract

Background: Comparing continuous films taken at different timescales is a way to study the alveolar bone changes around the implant over time. One of the important concerns in quantitative analysis of the alveolar bone changes over the time is to reduce variations in the X-ray imaging geometry and image density. Methods : Using a modified XCP film holder together with the bite recording material, parallel periapical radiographs were taken from the implants placements of 16 patients in four steps. Densities of radiographs were measured in a conventional way using the video densitometry device. The same films were also scanned; sequential radiographic density of each patient was homogenised and the density was measured. Density changes obtained in both methods were compared. The data were evaluated using ANOVA, paired t-test and Pearson correlation (α = 0.05). Results: In the conventional method of densitometry, the average densities were as follows: before operation 1.0044, after one week 0.9600, after one month 0.9469 and after three months 0.9398. Also, in the standard method of densitometry, the average densities were as follows: before operation 111.7013, after one week 113.4225, after one month 119.4075 and after three months 131.1162. Average density in conventional densitometry were not significantly different in various time stages (P = 0.395). But, the standard densitometry method showed a significant difference (P = 0.001). Conclusion: The average density obtained at different stages in the standard densitometry showed a gradual increase in the bone density in the entire process. Standardising the patient′s consecutive radiographic images is essential for quantitative measurements over the time.

Citation

ID: 178852
Ref Key: naser2011dentalcomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
178852
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet