the effect of low flow inhalation anesthesia on operative hemodynamic condition in comparison with high flow anesthesia

the effect of low flow inhalation anesthesia on operative hemodynamic condition in comparison with high flow anesthesia

;M Eidi;H Hoseinzade;KH Kolahdozan;D Aghamohammadi
korean journal of food preservation 2007 Vol. 12 pp. 1-9
116
eidi2007armaghanethe

Abstract

Introduction & Objective: Low flow anesthesia technique in which the flow fresh gas is lower than minute volume of the patient results in improvement in the patient’s care such as reduction of operative hypothermia, reduction of postoperative shivering and leads to an increase in economical and enviornmental interests. The goal of the study was to investigate the patients’ operative hemodynamic variations using the high and low flow anesthesia techniques. Materials & Methods: This prospective, clincal and single blind study was carried out in Tbriz Emam Khomeini Hospital in 1384. In this study 97 patients in ASA class I or II after routine induction of G.A, during maintenance of anesthesia were randomly divided in two groups group I (high flow anesthesia) and group II (low flow anesthesia). For all patients ECG, HR, SPO2, BP, B.T, ETCO2 and inspiratory, expiratory percentage of O2, N2O, halothane, postoprative shievring and duration of oprations were recorded. 46 patients underwent high flow anesthesia and 51 patients underwent low flow anesthesia. Results: The average blood pressure in group I was as follow: preoperative, systol=13820 mmHg and diastol=7815 mmHg, intraoperative, systol=10531 mmHg and diastol=6410 mmHg and in recovery systol=11615 mmHg and diastol=7013 mmHg. In group II who had low flow anesthesia the blood pressure was found to be systol=13922 mmHg and diastol=7922 mmHg preoperative, systol=12221 mmHg and diastol=7517 mmHg intraoperative and systol=11815 mmHg and diastol=7717 mmHg in recovery. The differences in blood pressure in both group were statiscally significant (p=0.01). The average heart rate in group I was 9018 beat/min preoperative, 7014 intraoperative and 126 in recovery. The avrage heart rate in group II was 87.921 preoperative, 8616 intraoperative and 10417 in recovery. The differences were statiscally significant but there was no significant difference between the two groups with regard to sex, age and weight. Conclusion: Maintenance of anesthesia with low flow anesthesia gasses maintains more hemodynamic condition during operation.

Citation

ID: 178041
Ref Key: eidi2007armaghanethe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
178041
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet