A morphologically robust chaotic map based approach to embed patient's confidential data securely in non-QRS regions of ECG signal.

A morphologically robust chaotic map based approach to embed patient's confidential data securely in non-QRS regions of ECG signal.

Soni, Neetika;Saini, Indu;Singh, Butta;
australasian physical & engineering sciences in medicine 2019 Vol. 42 pp. 111-135
229
soni2019aaustralasian

Abstract

In e-healthcare paradigm, the physiological signals along with patient's personal information need to be transmitted to remote healthcare centres. Before sharing this sensitive information over the unsecured channel, it is prerequisite to protect it from unauthorised access. The proposed method explores ECG signal as the cover signal to hide patient's personal information without disturbing its diagnostic features. Chaotic maps are used to randomly select the embedding locations in the non-QRS region while excluding the sensitive QRS region of ECG train. Optimum Location Selection algorithm has been designed to select the embedding locations in non-QRS embedding region. The proposed algorithm is thoroughly examined and the distortion is measured in terms of statistical parameters and clinical measures such as PRD, PRDN, PRD1024, PSNR, SNR, MSE, MAE, KL-Divergence, WWPRD and WEDD. The robustness of the algorithm is verified using the parameters such as key space and key sensitivity. The implementation has been extensively tested on all the 48 records of the standard MIT-BIH Arrhythmia database, abnormal databases [CU-VT, BIDMC-CHF and PTB (leads I, II and III)] and self-recorded data of 20 subjects. The algorithm yields average PRD, MSE, KL-Divergence, PSNR, WWPRD and WEDD of 4.7 × 10, 1.13 × 10, 1.29 × 10, 50.28, 0.15 and 0.04 at an average maximum EC of 0.45(96876 bits) on MIT-BIH Arrhythmia database and 0.016, 3.38 × 10, 1.8 × 10, 46.03, 0.13 and 0.03 respectively at an average maximum EC of 0.47 (102571 bits) on self-recorded data which clearly reveals the competency of the proposed algorithm in comparison with the other state of the art ECG steganography approaches.

Citation

ID: 17359
Ref Key: soni2019aaustralasian
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
17359
Unique Identifier:
10.1007/s13246-018-00718-1
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet