estimating chlorophyll fluorescence parameters using the joint fraunhofer line depth and laser-induced saturation pulse (fld-lisp) method in different plant species

estimating chlorophyll fluorescence parameters using the joint fraunhofer line depth and laser-induced saturation pulse (fld-lisp) method in different plant species

;Parinaz Rahimzadeh-Bajgiran;Bayaer Tubuxin;Kenji Omasa
Journal of pharmacological sciences 2017 Vol. 9 pp. 599-
204
rahimzadeh-bajgiran2017remoteestimating

Abstract

A comprehensive evaluation of the recently developed Fraunhofer line depth (FLD) and laser-induced saturation pulse (FLD-LISP) method was conducted to measure chlorophyll fluorescence (ChlF) parameters of the quantum yield of photosystem II (ΦPSII), non-photochemical quenching (NPQ), and the photosystem II-based electron transport rate (ETR) in three plant species including paprika (C3 plant), maize (C4 plant), and pachira (C3 plant). First, the relationships between photosynthetic photon flux density (PPFD) and ChlF parameters retrieved using FLD-LISP and the pulse amplitude-modulated (PAM) methods were analyzed for all three species. Then the relationships between ChlF parameters measured using FLD-LISP and PAM were evaluated for the plants in different growth stages of leaves from mature to aging conditions. The relationships of ChlF parameters/PPFD were similar in both FLD-LISP and PAM methods in all plant species. ΦPSII showed a linear relationship with PPFD in all three species whereas NPQ was found to be linearly related to PPFD in paprika and maize, but not for pachira. The ETR/PPFD relationship was nonlinear with increasing values observed for PPFDs lower than about 800 μmol m−2 s−1 for paprika, lower than about 1200 μmol m−2 s−1 for maize, and lower than about 800 μmol m−2 s−1 for pachira. The ΦPSII, NPQ, and ETR of both the FLD-LISP and PAM methods were very well correlated (R2 = 0.89, RMSE = 0.05), (R2 = 0.86, RMSE = 0.44), and (R2 = 0.88, RMSE = 24.69), respectively, for all plants. Therefore, the FLD-LISP method can be recommended as a robust technique for the estimation of ChlF parameters.

Citation

ID: 168621
Ref Key: rahimzadeh-bajgiran2017remoteestimating
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
168621
Unique Identifier:
10.3390/rs9060599
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet