hand grip endurance test relates to clinical state and prognosis in copd patients better than 6-minute walk test distance

hand grip endurance test relates to clinical state and prognosis in copd patients better than 6-minute walk test distance

;Kovarik M;Joskova V;Patkova A;Koblizek V;Zadak Z;Hronek M
tijdschrift voor geneeskunde 2017 Vol. Volume 12 pp. 3429-3435
195
m2017internationalhand

Abstract

Miroslav Kovarik,1,2 Vera Joskova,1,2 Anna Patkova,1,2 Vladimir Koblizek,3 Zdenek Zadak,2 Miloslav Hronek1,2 1Department of Biological and Medical Sciences, Faculty of Pharmacy in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic; 2Department of Research and Development, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic; 3Department of Pulmonary Medicine, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic Purpose: Patients with COPD present peripheral muscle dysfunction and atrophy, expressed as muscle strength and endurance reduction. The goal of this study was direct dynamometric assessment of hand grip endurance and strength in relation to the stage of disease, multidimensional predictors of mortality, and 6-minute walk test (6MWT). To the best of our knowledge, there has been no previous study determining these parameters.Patients and methods: In this observational study, 58 consecutive outpatients with stable COPD and 25 volunteers without respiratory problems were compared. All COPD subjects underwent a comprehensive examination to determine COPD severity, prognostic scales, and 6MWT. Body composition, basic spirometric parameters, and hand grip strength and endurance were determined in all study participants.Results: Patients in the COPD group had a 15% decrease in maximum strength (P=0.012) and a 28% decrease in area under the force/time curve (AUC) of the endurance test (P<0.001) compared to the control group. Dynamometric parameters were significantly negatively associated with the stage of disease and values of multivariable prediction indexes, and positively associated with the results of 6MWT. In most cases, closer associations were found with AUC than with 6MWT and in the gender-specific groups.Conclusion: Both hand grip strength and endurance are impaired in COPD patients in comparison with the control group. In particular, AUC could be considered as an attractive option not only to assess exercise capacity but also as a predictive marker with a better prognostic value than 6MWT in COPD patients. This is the first study to observe the dependence of hand grip endurance on combined COPD assessment. Keywords: dynamometry, muscle strength, muscle endurance, BODE index

Citation

ID: 166821
Ref Key: m2017internationalhand
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
166821
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet