ratio of height-to-thyromental distance and ratio of height-to-sternomental distance as predictors of laryngoscopic grade in children

ratio of height-to-thyromental distance and ratio of height-to-sternomental distance as predictors of laryngoscopic grade in children

;Swarup Ray;Shwethapriya Rao;Jasvinder Kaur;Yogesh K Gaude
molecular ecology resources 2018 Vol. 34 pp. 68-72
150
ray2018journalratio

Abstract

Background and Aims: Failure to secure the airway is an important cause of morbidity and mortality in children. Children are often uncooperative for routine examination and pose problems for obtaining external measurements. We aimed to evaluate ratio of height-to-thyromental distance (RHTMD) and ratio of height-to-sternomental distance (RHSMD) as predictors of laryngoscopic grade in children aged 1–12 years. Material and Methods: This study was an observational study conducted in children aged between 1 and 12 years scheduled for elective surgery under general anesthesia. Children unable to stand, having limited mouth opening/neck mobility, cleft palate or with midline neck masses were excluded. Weight, height, and thyromental and sternomental distances were measured preoperatively. Following induction of anesthesia and full-muscle relaxation, laryngoscopy was performed and Cormack–Lehane view with Cook's modification was noted. Receiver operating characteristic (ROC) curve analysis using RHTMD and RHSMD was performed for predicting poor laryngoscopic view. Results: A total of 138 children with mean age of 6.6 ± 3.4, RHTMD of 17.7 ± 2.1, and RHSMD of 10.0 ± 1.0 were included. No Grade 3 or 4 laryngoscopic views were obtained. ROC curve analysis was done for predicting 2b view (restricted), incidence of which was 10.1%. RHTMD was a better predictor of 2b laryngoscopic view with an area under curve (AUC) of 0.792 compared to RHSMD (AUC = 0.463). Conclusions: In children aged 1–12 years, RHTMD is a better predictor of restricted view compared to RHSMD.

Citation

ID: 165961
Ref Key: ray2018journalratio
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
165961
Unique Identifier:
10.4103/joacp.JOACP_135_16
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet