the effect of oxybuprocaine on corneal thickness as measured with optical coherence tomography

the effect of oxybuprocaine on corneal thickness as measured with optical coherence tomography

;Rowen Govender;Zainab Y. Seedat;Aristha Ramdass;Rekha Hansraj;Nonkululeko M. Gcabashe
computers in human behavior 2016 Vol. 75 pp. e1-e5
187
govender2016africanthe

Abstract

Background: No previous study in South Africa has used optical coherence tomography (OCT) in assessing corneal thickness changes following the instillation of an anaesthetic. Aim: The purpose of this study was to investigate the short-term effects of oxybuprocaine 0.4% on corneal thickness. Setting: The study was conducted at a university eye clinic in Westville, KwaZulu-Natal. Methods: A total of 34 (N = 34) participants, of both genders, aged 18–25 years participated in the study. Data collection commenced once ethical clearance was obtained. Baseline measurements of central corneal thickness (CCT) (within 0 mm – 2 mm of the corneal apex) and mid-peripheral corneal thickness (MPCT) (within 2 mm – 5 mm of the corneal apex) were taken using the Optovue iVue 100 OCT. Measurements were obtained using the standard iVue 100 corneal pachymetry map. One drop of oxybuprocaine was then instilled using a sterile technique in the right eye (RE) of each participant. Central and MPCT measurements were obtained using the OCT at time intervals of 30 s for the first 2 min and then for 60-s intervals up until 5 min. Baseline central and MPCT were then measured for the left eye (LE) using the OCT. The effect of two drops of oxybuprocaine on CCT was also investigated on the left eye only using the same procedure as on the right eye. Results: There were minimal fluctuations of the CCT and MPCT in the 5 min following instillation of either one or two drops of oxybuprocaine. The fluctuation of both the CCT and MPCT was within 10 µm irrespective of dosage and returned to baseline thickness after 5 min. Conclusion: Clinically, short-term CCT and MPCT changes following the instillation of oxybuprocaine are not large enough to affect the accuracy of Goldmann applanation tonometry.

Citation

ID: 164982
Ref Key: govender2016africanthe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
164982
Unique Identifier:
10.4102/aveh.v75i1.326
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet