avaliação de pirogênios em produtos de uso veterinário pelos testes da hipertermia em coelhos e do lisado de amebócitos do limulus pyrogens in veterinary products by the rabbit pyrogen test and the limulus amoebocyte lysate test

avaliação de pirogênios em produtos de uso veterinário pelos testes da hipertermia em coelhos e do lisado de amebócitos do limulus pyrogens in veterinary products by the rabbit pyrogen test and the limulus amoebocyte lysate test

;Thiago Barth;Volmir João Dalmora;Felipe Bianchini D'Avila;Sérgio Luiz Dalmora
Trials 2007 Vol. 37 pp. 190-194
198
barth2007cinciaavaliao

Abstract

Realizou-se a avaliação de pirogênios em produtos veterinários de uso parenteral, pelo método da hipertermia em coelhos, calculando-se, para o teste das amostras, doses com concentrações de três a sete vezes superiores à terapêutica. Preconizou-se como resposta positiva o aumento de temperatura de 0,6°C. Utilizou-se também o ensaio do lisado de amebócitos do Limulus (LAL) por geleificação, semiquantitativo, executando o teste de interferentes, validando o procedimento e estabelecendo a máxima diluição válida para a análise de cada produto. Paralelamente, efetuou-se avaliação comparativa de amostras com o método do LAL cromogênico, quantitativo, demonstrando correlação e reprodutibilidade dos resultados. Avaliaram-se vinte e oito produtos de diferentes classes farmacológicas, observando-se que dois não cumpriram as especificações, sendo reprovados. Sugere-se que as especificações estudadas sejam adotadas, contribuindo para aprimorar o controle de contaminantes, garantindo a qualidade e a segurança dos produtos veterinários.
The rabbit pyrogen test was used to evaluate veterinary products, suggesting the temperature rise of 0.6°C as the ending point for the positive results. The test doses were calculated based on the therapeutic dose increased from three to seven times. The semi-quantitative Limulus amoebocyte lysate (LAL) gel clot test was performed and compared to the LAL spectrophotometric chromogenic, quantitative assay. The comparative evaluation of the samples showed correlation and reproducibility of the results. The interference test was carried out, the procedure validated and the maximum valid dilution established for the analysis of the products without Pharmacopoeial specifications. Two of the twenty-eight products of different pharmacological groups evaluated didn't meet the requirements and were reproved. The specifications investigated are suggested to be used for the purity evaluation of the veterinary parenteral products, as a contribution to assure the quality and safety of the products.

Keywords

Citation

ID: 164614
Ref Key: barth2007cinciaavaliao
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
164614
Unique Identifier:
10.1590/S0103-84782007000100030
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet