differential column measurements using compact solar-tracking spectrometers

differential column measurements using compact solar-tracking spectrometers

;J. Chen;J. Chen;C. Viatte;J. K. Hedelius;T. Jones;J. E. Franklin;H. Parker;E. W. Gottlieb;P. O. Wennberg;M. K. Dubey;S. C. Wofsy
Journal of agricultural and food chemistry 2016 Vol. 16 pp. 8479-8498
118
chen2016atmosphericdifferential

Abstract

We demonstrate the use of compact solar-tracking Fourier transform spectrometers (Bruker EM27/SUN) for differential measurements of the column-averaged dry-air mole fractions of CH4 and CO2 within urban areas. Using Allan variance analysis, we show that the differential column measurement has a precision of 0.01 % for XCO2 and XCH4 with an optimum integration time of 10 min, corresponding to Allan deviations of 0.04 ppm and 0.2 ppb, respectively. The sensor system is very stable over time and after relocation across the continent. We report tests of the differential column measurement, and its sensitivity to emission sources, by measuring the downwind-minus-upwind column difference ΔXCH4 across dairy farms in the Chino area, California, and using the data to verify emissions reported in the literature. Ratios of spatial column differences ΔXCH4∕ΔXCO2 were observed across Pasadena within the Los Angeles basin, indicating values consistent with regional emission ratios from the literature. Our precise, rapid measurements allow us to determine significant short-term variations (5–10 min) of XCO2 and XCH4 and to show that they represent atmospheric phenomena.

Overall, this study helps establish a range of new applications for compact solar-viewing Fourier transform spectrometers. By accurately measuring the small differences in integrated column amounts across local and regional sources, we directly observe the mass loading of the atmosphere due to the influence of emissions in the intervening locale. The inference of the source strength is much more direct than inversion modeling using only surface concentrations and less subject to errors associated with small-scale transport phenomena.

Citation

ID: 164137
Ref Key: chen2016atmosphericdifferential
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
164137
Unique Identifier:
10.5194/acp-16-8479-2016
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet