evaluation of development in indirect determination of milk fat free fatty acids in czech republic

evaluation of development in indirect determination of milk fat free fatty acids in czech republic

;Oto Hanuš;Eva Samková;Jan Říha;Marcela Vyletělová Klimešová;Petr Roubal
Talanta 2013 Vol. 61 pp. 1669-1679
195
hanu2013actaevaluation

Abstract

Free fatty acids (FFAs) in fat are important indicator of raw milk quality. Result reliability of FFAs is important. Aim was to verify MIR–FT (mid infrared spectroscopy with Fourier’s transformations) method for its calibration to determine FFAs, time stability of MIR–FT FFA calibration and calibration levelling in laboratory networks. Reference (RE) milk samples (1 set = 8) were prepared according to CSN 57 0533 (FFAs in mmol.100g−1 of fat). MIR–FT instruments were: 1 LactoScope FTIR (DE); 2 Bentley FTS (BE); 2 MilkoScan FT 6000 (FO). 3 calibrations of MIR–FT (5) in 3 laboratories were performed. Bulk milk samples came from 4 herds and 2 breeds. These 4 samples were used for calibration in native and modified form. Modification increased FFAs by cca 100%. Calibration set had 8 samples. 1 between calibration interval was checked monthly by proficiency testing (PT). PT set had 10 samples. 5 samples were with native milk and 5 had modified fat content, lower and higher. Maximal value of difference variability for calibration quality validation is x (sd of difference MIR–FT and RE) plus 1.64 multiple of sd (on 95% level), 1.0613 mmol.100g−1. Mean validation correlation coefficient (r) between MIR–FT and RE results was 0.802 ± 0.082 (P < 0.001), from 0.666 to 0.945. Minimal value at calibration is x minus 1.64 multiple of sd (0.668). Correlations between MIR–FT results were higher by 8.4% (0.869 (P < 0.001) > 0.802). Example PT with 10 and 5 milk samples had similar results of r 0.887 and 0.953 (P < 0.001 and P < 0.05). There is possibility to construct a levelling programme for calibrated instruments. Some equation between PT reference and instrumental values could correct MIR–FT results for their better comparability.

Citation

ID: 163769
Ref Key: hanu2013actaevaluation
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
163769
Unique Identifier:
10.11118/actaun201361061669
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet