influência da estratégia ventilatória no desempenho funcional de enxertos pulmonares em um modelo experimental de transplante pulmonar unilateral de doadores após parada cardiocirculatória ventilation strategy and its influence on the functional performance of lung grafts in an experimental model of single lung transplantation using non-heart-beating donors

influência da estratégia ventilatória no desempenho funcional de enxertos pulmonares em um modelo experimental de transplante pulmonar unilateral de doadores após parada cardiocirculatória ventilation strategy and its influence on the functional performance of lung grafts in an experimental model of single lung transplantation using non-heart-beating donors

;Elaine Aparecida Felix;Cristiano Feijó Andrade;Paulo Francisco Guerreiro Cardoso;Gabriela Cury Thiesen;Ana Carolina Peçanha Antonio;Lucas Krieger Martins;Tiago Antonio Tonietto
cryobiology 2010 Vol. 36 pp. 554-561
269
felix2010jornalinfluncia

Abstract

OBJETIVO: Comparar a influência de duas estratégias ventilatórias - ventilação controlada a volume (VCV) e ventilação controlada a pressão (VCP) - no desempenho funcional de enxertos pulmonares em um modelo canino de transplante pulmonar unilateral esquerdo, utilizando-se doadores cujos pulmões foram captados após três horas de parada cardiocirculatória em temperatura ambiente e sob ventilação mecânica. MÉTODOS: O estudo incluiu 40 cães mestiços randomizados nos grupos VCV e VCP. Dos 20 receptores, 5 não sobreviveram ao transplante, e 5 não sobreviveram ao período de avaliação pós-transplante. Os 10 receptores sobreviventes (5 em cada grupo) foram avaliados durante 360 min após o término do transplante pulmonar. O desempenho funcional dos enxertos foi estudado através da avaliação da mecânica respiratória, trocas gasosas e histologia do enxerto. RESULTADOS: Não houve diferenças significativas entre os grupos quanto às variáveis de mecânica respiratória (pressão de pico inspiratória, pressão de platô, pressão média de vias aéreas, complacência dinâmica e complacência estática) e de trocas gasosas (PaO2, pressão venosa mista de oxigênio, PaCO2, pressão venosa mista de CO2 e diferença arteriovenosa de oxigênio). As alterações histopatológicas foram compatíveis com o padrão de lesão pulmonar aguda não específica e não diferiram entre os grupos. CONCLUSÕES: Este modelo de transplante pulmonar mostrou que o desempenho funcional do enxerto não foi influenciado pela estratégia ventilatória utilizada até seis horas após a reperfusão.
OBJECTIVE: To compare the influence of two different ventilation strategies-volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV)-on the functional performance of lung grafts in a canine model of unilateral left lung transplantation using donor lungs harvested after three hours of normothermic cardiocirculatory arrest under mechanical ventilation. METHODS: The study comprised 40 mongrel dogs, randomized into two groups: VCV and PCV. Of the 20 recipients, 5 did not survive the transplant, and 5 died before the end of the post-transplant assessment period. The remaining 10 survivors (5 in each group) were evaluated for 360 min after lung transplantation. The functional performance of the grafts was evaluated regarding respiratory mechanics, gas exchange, and lung graft histology. RESULTS: There were no significant differences between the groups regarding respiratory mechanics (peak inspiratory pressure, plateau pressure, mean airway pressure, dynamic compliance, and static compliance) or gas exchange variables (PaO2, venous oxygen tension, PaCO2, venous carbon dioxide tension, and the arterial-venous oxygen content difference). The histopathological findings were consistent with nonspecific acute lung injury and did not differ between the groups. CONCLUSIONS: This model of lung transplantation showed that the functional performance of lung grafts was not influenced by the ventilation strategy employed during the first six hours after reperfusion.

Citation

ID: 163154
Ref Key: felix2010jornalinfluncia
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
163154
Unique Identifier:
10.1590/S1806-37132010000500006
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet