robotic mitral valve replacement: a single center, medium-long term follow-up of 43 cases

robotic mitral valve replacement: a single center, medium-long term follow-up of 43 cases

;Guo-peng LIU;Chang-qing GAO;Ming YANG;Cang-song XIAO;Gang WANG;Jia-li WANG;Yao WANG;Yue ZHAO
frontiers in neurorobotics 2017 Vol. 42 pp. 549-552
204
liu2017medicalrobotic

Abstract

Objective To summarize the surgical experience gained from robotic mitral valve replacement (MVR), and demonstrate the long-term clinical follow-up results. Methods From Jan. 2007 to Jan. 2015, more than 700 patients underwent various types of robotic cardiac surgery in the Department the authors served in, and of them 43 patients underwent robotic MVR with da Vinci Surgical System (Intuitive Surgical, USA). Among the 43 patients, the average age was 47±11 years (ranged 19-65 years), and sex ratio (female to male) was 0.8:1. Six patients were with heart function of NYHA class Ⅰ, 30 patients were of NYHA class Ⅱ and 7 patients were of NYHA class Ⅲ. The left ventricular ejection fraction (LVEF) were 54%-78% (64.0%±7.1%), and 20 patients had atrial fibrillation on admission, and 35 patients were with rheumatic mitral stenosis (MS). Atrial septal defect (0.7cm in size) co-existed in 1 case and 1 patient had mild aortic regurgitation. Mechanical or bioprosthetic mitral valve was replaced via left atriotomy by using da Vinci robotic surgical system after cardiopulmonary bypass (CPB) set-up. Radiopaque titan clips was employed by Cor-Knot knot-tying device (LSI Solutions, Inc, Victor, NY) to anchor the prosthetic valve. Trans-esophageal echocardiography (TEE) was performed before and after surgery. The operative data were collected and patients were followed up at outpatient clinic regularly up to 6 years. Results All cases were performed successfully with the same surgery. No conversion to median sternotomy or operative mortality occurred. The average operation time was 292±62 minutes (ranged 140-450 minutes) with CPB time of 124±26 minutes and aortic occlusion time of 88±21 minutes. The postoperative mechanical ventilation support time was continued for 15±6 hours, and the average staying length in critical care unit was 4±1 days. No myocardial infarction, ventricular tachycardia or excessive bleeding was complicated. All patients were successfully followed up for a median of 3.5 years (ranged 1 month to 6 years). In the follow-up period, no incidence of death, stroke, re-operation due to prosthetic endocarditis or prosthetic failure was reported. However, 39.5% (n=17) patients still had atrial fibrillation after surgery. Conclusion Robotic MVR is a safe and effective procedure with excellent long term surgical outcome. DOI: 10.11855/j.issn.0577-7402.2017.06.13

Citation

ID: 162374
Ref Key: liu2017medicalrobotic
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
162374
Unique Identifier:
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet