quantitative myocardial perfusion with dynamic contrast-enhanced imaging in mri and ct: theoretical models and current implementation

quantitative myocardial perfusion with dynamic contrast-enhanced imaging in mri and ct: theoretical models and current implementation

;G. J. Pelgrim;A. Handayani;H. Dijkstra;N. H. J. Prakken;R. H. J. A. Slart;M. Oudkerk;P. M. A. Van Ooijen;R. Vliegenthart;P. E. Sijens
spectrochimica acta - part a: molecular and biomolecular spectroscopy 2016 Vol. 2016 pp. -
85
pelgrim2016biomedquantitative

Abstract

Technological advances in magnetic resonance imaging (MRI) and computed tomography (CT), including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET). This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD), as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

Keywords

Citation

ID: 152779
Ref Key: pelgrim2016biomedquantitative
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
152779
Unique Identifier:
10.1155/2016/1734190
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet