application of a serum protein signature for pancreatic cancer to separate cases from controls in a pancreatic surveillance cohort

application of a serum protein signature for pancreatic cancer to separate cases from controls in a pancreatic surveillance cohort

;Thomas P. Potjer;Bart J. Mertens;Simone Nicolardi;Yuri E. M van der Burgt;Bert. A. Bonsing;Wilma E. Mesker;Rob A. E. M Tollenaar;Hans F. A Vasen
advances in acoustics and vibration 2016 Vol. 9 pp. 242-247
9
potjer2016translationalapplication

Abstract

BACKGROUND: Pancreatic cancer (PC) surveillance is currently offered to individuals with a genetic predisposition to PC, but routinely used radiological screening modalities are not entirely reliable in detecting early-stage PC or its precursor lesions. We recently identified a discriminating PC biomarker signature in a sporadic patient cohort. In this study, we investigated if protein profiling can accurately distinguish PC from non-PC in a pancreatic surveillance cohort of genetically predisposed individuals. METHODS: Serum samples of 66 individuals with a CDKN2A germline mutation who participated in the pancreatic surveillance program (5 cases, 61 controls) were obtained following a standardized protocol. After sample clean-up, peptide and protein profiles were obtained on an ultrahigh-resolution matrix-assisted laser desorption/ionization–Fourier transform ion cyclotron resonance mass spectrometry platform. A discriminant score for each sample was calculated with a previously designed prediction rule, and the median discriminant scores of cases and controls were compared. Individuals with precursor lesions of PC (n = 4) and individuals with a recent diagnosis of melanoma (n = 4) were also separately considered. RESULTS: Cases had a higher median discriminant score than controls (0.26 vs 0.016; P = .001). The only individual with pathologically confirmed precursor lesions of PC could also be clearly distinguished from controls, and having a (recent) medical history of melanoma did not influence the protein signatures. CONCLUSIONS: Peptide and protein signatures are able to accurately distinguish PC cases from controls in a pancreatic surveillance setting. Mass spectrometry–based protein profiling therefore seems to be a promising candidate for implementation in the pancreatic surveillance program as an additional screening modality.

Citation

ID: 152158
Ref Key: potjer2016translationalapplication
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
152158
Unique Identifier:
10.1016/j.tranon.2016.03.003
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet