detection of ofloxacin resistance by nitrate reductase assay in mycobacterium tuberculosis isolates from extrapulmonary tuberculosis

detection of ofloxacin resistance by nitrate reductase assay in mycobacterium tuberculosis isolates from extrapulmonary tuberculosis

;Neeta Shrivastava;Reena Set;Sheetal Bankar;Jayanthi Shastri
bjog : an international journal of obstetrics and gynaecology 2017 Vol. 35 pp. 69-73
178
shrivastava2017indiandetection

Abstract

Context: Increased use of fluoroquinolones to treat community-acquired infections has led to the decreased susceptibility to Mycobacterium tuberculosis. There is a paucity of data on ofloxacin (OFX) resistance detection by nitrate reductase assay (NRA). Hence, the present study was carried out to find the efficacy of NRA for detection of OFX resistance in M. tuberculosis isolated from extrapulmonary tuberculosis (EPTB) cases. Aims: (1) To compare sensitivity, specificity and median time required to obtain results by NRA with economic variant proportion method (PM) for detection of OFX resistance.(2) To determine the extent of OFX resistance in clinical isolates of M. tuberculosis. Settings and Design: Seventy-three M. tuberculosis isolates from cases of EPTB were subjected to economic variant of PM for isoniazid, rifampicin and OFX. NRA was done for detection of OFX resistance. Subjects and Methods: Seventy-three isolates from clinical samples of suspected EPTB received in the Department of Microbiology were included in the study. Drug susceptibility test was performed on Lowenstein–Jensen medium with and without drugs. Statistical Analysis Used: Of turnaround time was done by Mann–Whitney test on SPSS (version 19, released in 2010, IBM Corp, Armonk NY),P < 0.05. Results: OFX resistance was seen in nine isolates. The sensitivity and specificity of OFX resistance by NRA was 100% and 96.87%, respectively. Median time required to obtain results by NRA was 10 days as compared to 28 days by PM. Conclusions: NRA is a specific and sensitive method for detection of OFX resistance in resource-restricted settings.

Citation

ID: 145517
Ref Key: shrivastava2017indiandetection
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
145517
Unique Identifier:
10.4103/ijmm.IJMM_16_266
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet