performance of quantitative ultrasound and six osteoporosis risk indexes in menopausal women: validation and comparative evaluation study.

performance of quantitative ultrasound and six osteoporosis risk indexes in menopausal women: validation and comparative evaluation study.

;Imad GHOZLANI;Aziza MOUNACH;Mirieme GHAZI;Radouane NIAMANE;Abdellah EL MAGHRAOUI
international journal of medicine and surgery 2016 Vol. 3 pp. 40-46
79
ghozlani2016internationalperformance

Abstract

Background: A number of questionnaire-based systems and the use of portable quantitative ultrasound scanners (QUS) have been devised in an attempt to produce a cost-effective method of screening for osteoporosis.
Objective: to assess the sensitivity and specificity of different techniques and their ability to act as screening tools in relation to dual energy X-ray absorptiometry (DXA).
Methods: 295 white postmenopausal women aged over 60 were enrolled. Each subject completed a standardized questionnaire which permits the measure of six osteoporosis indexes and had bone mineral density (BMD) measured using QUS and DXA. Sensitivity and specificity of the different techniques in relation to DXA were plotted as receiver-operating characteristic (ROC) curves at DXA T-score total hip ≤ -2.5 (osteoporosis).
Results: BUA sensitivity and specificity values were respectively 76.8% and 51.2% at the total hip. The optimal cut-off T-score for QUS was -2 at the total hip. The osteoporosis self-assessment tool (OST) provided consistently the highest AUC (0.80) among the clinical tools and had the best sensitivity and specificity balance (90.2%-44.5%). OST negative likelihood ratio was 0.22.
Conclusion: OST (based only on the weight and the age) performed slightly better than QUS and other risk questionnaires in predicting low BMD at the total hip

Citation

ID: 145048
Ref Key: ghozlani2016internationalperformance
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
145048
Unique Identifier:
10.15342/ijms.v3i2.111
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet