optimization of 3d planning dosimetry in a breast phantom for the match region of supraclavicular and tangential fields

optimization of 3d planning dosimetry in a breast phantom for the match region of supraclavicular and tangential fields

;Somayeh Nourollahi;Mahmoud Allahverdi;Mahbod Esfahani;Mehdi Aghili;Vahid Changizi
the international archives of the photogrammetry, remote sensing and spatial information sciences 2011 Vol. 8 pp. 73-81
206
nourollahi2011iranianoptimization

Abstract

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and tangential fields, utilizing Gafchromic EBT film for dosimetry. Material and Methods: In this study, a slab phantom was designed with lung- and heart-equivalent inhomogetenities. Our measurements were carried out using Gafchromic EBT film. Irradiations were performed using the 6 MV photon beam of a Varian 2100 Clinac linear accelerator. Three-dimensional treatment planning and dose calculations were carried out using the RT Dose Plan software. The conventional method with source-to-skin distance match and a 3D method with source-to-axis distance match under different combinations of parameters such as gantry, collimator and couch rotations as well as asymmetric fields were utilized. Results: The results demonstrated differences between the 3D and conventional techniques. The best results in the match region were observed using the 3D method with asymmetric technique (maximum area of overlap = 0.43 cm2, depth of overlap = 3.55 cm, and average width of overlap = 0.75 cm). Discussion and Conclusion: This study shows that the EBT film is a suitable tool for two-dimensional distribution dosimetry and relative dose measurements. The study shows difficulties in achieving a homogenous dose distribution in the match region of supraclavicular and tangential fields and also demonstrates the effects of setup parameters on matching of treatment fields.

Citation

ID: 142419
Ref Key: nourollahi2011iranianoptimization
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
142419
Unique Identifier:
10.22038/ijmp.2011.7231
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet