double-gap-in-roof reentrant tachycardia following surgical thoracoscopic atrial fibrillation ablation

double-gap-in-roof reentrant tachycardia following surgical thoracoscopic atrial fibrillation ablation

;Pavel Osmancik;Jana Zdarska;Petr Budera;Zbynek Straka
Medical decision making : an international journal of the Society for Medical Decision Making 2015 Vol. 15 pp. 172-176
160
osmancik2015indiandouble-gap-in-roof

Abstract

A case of macro-reentrant tachycardia associated with a box lesion after thoracoscopis left atrial surgical atrial fibrillation (AF) ablation yet to be described. The goal was to clarify the mechanisms and electrophysiological characteristics of this type of tachycardia. A patient was admitted for an EP study following surgical thoracoscopic AF ablation (box lexion formation by right-sided Cobra thoracoscopic ablation). Thoracoscopic ablation was done as the first step of the hybrid ablation approach to the persistent AF; the second step was the EP study. At the EP study, he presented with incessant regular tachycardia (cycle length of 226 ms). An EP study with conventional, 3D activation and entrainment mapping was done to assess the tachycardia mechanism. Two conduction gaps in the superior line (roofline) between the superior pulmonary veins were discovered. The tachycardia was successfully treated with a radiofrequency application near the gap close to the left superior pulmonary vein; however, following tachycardia termination, pulmonary vein isolation was absent. A second radiofrequency application, close to the roof of the right superior pulmonary, vein closed the gap in the box and led to the isolation of all 4 pulmonary veins. No atrial tachycardia recurred during the 6-month follow-up. Conduction gaps in box lesion created by thoracospcopic ablation can present as a novel type of man-made tachycardia after surgical ablation of atrial fibrillation. Activation and entrainment mapping is necessary for an accurate diagnosis.

Citation

ID: 133728
Ref Key: osmancik2015indiandouble-gap-in-roof
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
133728
Unique Identifier:
10.1016/j.ipej.2015.09.008
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet