CT portography by direct intrasplenic contrast injection: a new technique

CT portography by direct intrasplenic contrast injection: a new technique

R. Jain;S. Sawhney;P. Sahni;K. Taneja;M. Berry;R. Jain;S. Sawhney;P. Sahni;K. Taneja;M. Berry;
abdominal imaging 2014 Vol. 24 pp. 272-277
162
jain2014abdominalct

Abstract

Background: The evaluation of percutaneous contrast injection into splenic parenchyma as an alternative technique for computed tomographic (CT) portography in the preoperative assessment of primary hepatobiliary tumors. Methods: Thirty-two patients underwent a nonenhanced CT scan of the liver, after which a 19-gauge, 10-cm-long needle was introduced into the splenic parenchyma under CT guidance. One hundred forty milliliters of contrast medium (200 mgI/mL; 28 g/I) were injected through this needle: first, a 20-mL bolus (in 5 s) and then 2 mL/s for 60 s. At the end of the bolus injection (5 s), 8-mm-thick contiguous axial scans of the liver were obtained. Results: The success rate of the procedure was 93.7% (30/32; two technical failures). The average time required for the entire study was 13 min and 50 s (range = 7 min 53 s to 25 min 17 s). Hepatic parenchymal enhancement was good in 24/30 (80%), moderate in 3/30 (10%), and unsatisfactory in caudal sections of the liver in 3/30 (10%). Artifactual perfusion defects were seen in 4/30 (13%) due to inadvertant injection of small quantities of air. Intrasplenic subcapsular contrast accumulation occurred in 56.2% (18/32; minimal 15, moderate 3), extrasplenic contrast leakage in 12.5% (4/32), and left shoulder pain in 18.7% (6/32). No major complications were observed. Conclusions: Direct intrasplenic contrast injection for CT portography is a simple, effective, and safe technique with a high success rate and requires significantly less time and lower doses of contrast medium; it also eliminates angiography, indwelling arterial catheters, and patient transfers from angiography to the CT area.

Citation

ID: 118156
Ref Key: jain2014abdominalct
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
118156
Unique Identifier:
doi:10.1007/s002619900494
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet