Comparison of Drusen Volume Assessed by Two Different OCT Devices

Comparison of Drusen Volume Assessed by Two Different OCT Devices

Marco Beck;Devika S. Joshi;Lieselotte Berger;Gerd Klose;Sandro De Zanet;Agata Mosinska;Stefanos Apostolopoulos;Andreas Ebneter;Martin S. Zinkernagel;Sebastian Wolf;Marion R. Munk;Beck, Marco;Joshi, Devika S.;Berger, Lieselotte;Klose, Gerd;De Zanet, Sandro;Mosinska, Agata;Apostolopoulos, Stefanos;Ebneter, Andreas;Zinkernagel, Martin S.;Wolf, Sebastian;Munk, Marion R.;
journal of clinical medicine 2020 Vol. 9 pp. 2657-
225
beck2020journalcomparison

Abstract

To compare drusen volume between Heidelberg Spectral Domain (SD-) and Zeiss Swept-Source (SS) PlexElite Optical Coherence Tomography (OCT) determined by manual and automated segmentation methods. Thirty-two eyes of 24 patients with Age-Related Macular Degeneration (AMD) and drusen maculopathy were included. In the central 1 and 3 mm ETDRS circle drusen volumes were calculated and compared. Drusen segmentation was performed using automated manufacturer algorithms of the two OCT devices. Then, the automated segmentation was manually corrected and compared and finally analyzed using customized software. Though on SD-OCT, there was a significant difference of mean drusen volume prior to and after manual correction (mean difference: 0.0188 ± 0.0269 mm3, p < 0.001, corr. p < 0.001, correlation of r = 0.90), there was no difference found on SS-OCT (mean difference: 0.0001 ± 0.0003 mm3, p = 0.262, corr. p = 0.524, r = 1.0). Heidelberg-acquired mean drusen volume after manual correction was significantly different from Zeiss-acquired drusen volume after manual correction (mean difference: 0.1231 ± 0.0371 mm3, p < 0.001, corr. p < 0.001, r = 0.68). Using customized software, the difference of measurements between both devices decreased and correlation among the measurements improved (mean difference: 0.0547 ± 0.0744 mm3, p = 0.02, corr. p = 0.08, r = 0.937). Heidelberg SD-OCT, the Zeiss PlexElite SS-OCT, and customized software all measured significantly different drusen volumes. Therefore, devices/algorithms may not be interchangeable. Third-party customized software helps to minimize differences, which may allow a pooling of data of different devices, e.g., in multicenter trials.

Citation

ID: 115834
Ref Key: beck2020journalcomparison
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
115834
Unique Identifier:
10.3390/jcm9082657
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet