Calibration of high voltages at the ppm level by the difference of $$^{83{\mathrm{m}}}$$Kr conversion electron lines at the KATRIN experiment

Calibration of high voltages at the ppm level by the difference of $$^{83{\mathrm{m}}}$$Kr conversion electron lines at the KATRIN experiment

M. Arenz,W.-J. Baek,M. Beck,A. Beglarian,Jan D. Behrens,T. Bergmann,A. Berlev,U. Besserer,K. Blaum,T. Bode,B. Bornschein,T. Brunst,N. Buzinsky,S. Chilingaryan,W. Q. Choi,M. Deffert,P. J. Doe,O. Dragoun,G. Drexlin,S. Dyba,F. Edzards,K. Eitel,E. Ellinger,R. Engel,S. Enomoto,M. Erhard,D. Eversheim,M. Fedkevych,S. Fischer,J. A. Formaggio,F. M. Fränkle,G. B. Franklin,F. Friedel,A. Fulst,W. Gil,F. Glück,A. Gonzalez Urena,S. Grohmann,R. Grössle,R. Gumbsheimer,M. Hackenjos,V. Hannen,F. Harms,N. Haußmann,F. Heizmann,K. Helbing,W. Herz,S. Hickford,D. Hilk,D. Hillesheimer,M. A. Howe,A. Huber,A. Jansen,J. Kellerer,N. Kernert,L. Kippenbrock,M. Kleesiek,M. Klein,Andreas Kopmann,M. Korzeczek,A. Kovalík,B. Krasch,M. Kraus,L. Kuckert,T. Lasserre,Ondřej Lebeda,J. Letnev,A. Lokhov,M. Machatschek,A. Marsteller,E. L. Martín,S. Mertens,Sebastian Mirz,B. Monreal,H. Neumann,S. Niemes,A. Off,A. Osipowicz,E. Otten,Diana Parno,A. Pollithy,A. W. P. Poon,F. Priester,P. C.-O. Ranitzsch,O. Rest,R. G. H. Robertson,F. Roccati,C. Rödenbeck,M. Röllig,C. Röttele,M. Ryšavý,R. Sack,A. Saenz,L. Schimpf,K. Schlösser,K. Schönung,M. Schrank,H. Seitz-Moskaliuk,J. Sentkerestiová,V. Sibille,M. Slezak,M. Steidl,N. Steinbrink,M. Sturm,M. Suchopár,M. Suesser,H. H. Telle,L. A. Thorne,T. Thümmler,N. Titov,I. Tkachev,N. Trost,K. Valerius,D. Venos,R. Vianden,A. P. Vizcaya Hernández,M. Weber,C. Weinheimer,C. Weiss,S. Welte,J. Wendel,J. F. Wilkerson,J. Wolf,S. Wüstling,S. Zadoroghny,L. Bornschein,M. Schlosser;M. Arenz;W.-J. Baek;M. Beck;A. Beglarian;Jan D. Behrens;T. Bergmann;A. Berlev;U. Besserer;K. Blaum;T. Bode;B. Bornschein;T. Brunst;N. Buzinsky;S. Chilingaryan;W. Q. Choi;M. Deffert;P. J. Doe;O. Dragoun;G. Drexlin;S. Dyba;F. Edzards;K. Eitel;E. Ellinger;R. Engel;S. Enomoto;M. Erhard;D. Eversheim;M. Fedkevych;S. Fischer;J. A. Formaggio;F. M. Fränkle;G. B. Franklin;F. Friedel;A. Fulst;W. Gil;F. Glück;A. Gonzalez Urena;S. Grohmann;R. Grössle;R. Gumbsheimer;M. Hackenjos;V. Hannen;F. Harms;N. Haußmann;F. Heizmann;K. Helbing;W. Herz;S. Hickford;D. Hilk;D. Hillesheimer;M. A. Howe;A. Huber;A. Jansen;J. Kellerer;N. Kernert;L. Kippenbrock;M. Kleesiek;M. Klein;Andreas Kopmann;M. Korzeczek;A. Kovalík;B. Krasch;M. Kraus;L. Kuckert;T. Lasserre;Ondřej Lebeda;J. Letnev;A. Lokhov;M. Machatschek;A. Marsteller;E. L. Martín;S. Mertens;Sebastian Mirz;B. Monreal;H. Neumann;S. Niemes;A. Off;A. Osipowicz;E. Otten;Diana Parno;A. Pollithy;A. W. P. Poon;F. Priester;P. C.-O. Ranitzsch;O. Rest;R. G. H. Robertson;F. Roccati;C. Rödenbeck;M. Röllig;C. Röttele;M. Ryšavý;R. Sack;A. Saenz;L. Schimpf;K. Schlösser;K. Schönung;M. Schrank;H. Seitz-Moskaliuk;J. Sentkerestiová;V. Sibille;M. Slezak;M. Steidl;N. Steinbrink;M. Sturm;M. Suchopár;M. Suesser;H. H. Telle;L. A. Thorne;T. Thümmler;N. Titov;I. Tkachev;N. Trost;K. Valerius;D. Venos;R. Vianden;A. P. Vizcaya Hernández;M. Weber;C. Weinheimer;C. Weiss;S. Welte;J. Wendel;J. F. Wilkerson;J. Wolf;S. Wüstling;S. Zadoroghny;L. Bornschein;M. Schlosser;
the european physical journal c 2018 Vol. 78 pp. 368-
209
schlosser2018thecalibration

Abstract

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at − 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two \(^{83{\mathrm{m}}}\)Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN’s commissioning measurements in July 2017. The measured scale factor \(M=1972.449(10)\) of the high-voltage divider K35 is in agreement with the last PTB calibration 4 years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.

Citation

ID: 113610
Ref Key: schlosser2018thecalibration
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
113610
Unique Identifier:
10.1140/epjc/s10052-018-5832-y
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet