Fluctuant tonus of the coronary arteries possibly documented by repeated multidetector row computed tomography

Fluctuant tonus of the coronary arteries possibly documented by repeated multidetector row computed tomography

Ikuko Anan;Kenichi Hongo;Makoto Kawai;Kazuo Ogawa;Toru Sakuma;Kunihiko Fukuda;Ikuo Taniguchi;Michihiro Yoshimura;
research reports in clinical cardiology 2014 Vol. 5 pp. 327--337
261
anan2014fluctuantresearch

Abstract

Fluctuant tonus of the coronary arteries possibly documented by repeated multidetector row computed tomography Ikuko Anan,1 Kenichi Hongo,1 Makoto Kawai,1 Kazuo Ogawa,1 Toru Sakuma,2 Kunihiko Fukuda,2 Ikuo Taniguchi,1 Michihiro Yoshimura1 1Division of Cardiology, Department of Internal Medicine, 2Department of Radiology, The Jikei University School of Medicine, Tokyo, Japan Objective: Recent advances in multidetector row computed tomography (MDCT) have made it possible to diagnose coronary stenosis with high sensitivity. However, coronary arterial tonus has not been considered when reading MDCT. We hypothesized that MDCT can document fluctuant tonus of the coronary arteries. Methods: The study population consisted of 39 consecutive patients who underwent MDCT twice in our institution with 64-row dual-source MDCT. Measurements were performed with stretched multiplanar reconstruction images using the full width at half maximum method. The coronary arteries were measured at each segment, and the same measurement was performed in the ascending aorta and the left internal thoracic artery (ITA). The percent diameter changes between the first and second measurements were examined in each segment of the coronary arteries and compared with those in the aorta or the ITA. Results: The average percent diameter changes were statistically equivalent between the coronary arteries and the aorta or the ITA. On the other hand, the percent diameter changes in distribution were significantly larger in the coronary arteries than those in the aorta or the ITA. This suggests that the diameter of the coronary arteries is liable to show variation compared to that of other arteries. Conclusion: This study confirmed for the first time that coronary arteries can fluctuate substantially and that these changes can be documented by MDCT. Changes in coronary arterial tonus should therefore be considered when reading MDCT. Keywords: coronary spastic angina, coronary arterial tonus, false positive study

Citation

ID: 11068
Ref Key: anan2014fluctuantresearch
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
11068
Unique Identifier:
10.2147/RRCC.S72464
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet