Comparison of safety and outcomes with two approaches to the mitral valve.

Comparison of safety and outcomes with two approaches to the mitral valve.

Izzat, Mohammad Bashar;Aljasem, Hazem;Alsharabi, Mohannad;Hafez, Abdullatif;
journal of cardiac surgery 2020
215
izzat2020comparisonjournal

Abstract

The efficacy of the superior trans-septal (STS) approach to the mitral valve has been offset by the perceived risks of adverse postoperative events. The aim of this study was to review our experience with using the left atriotomy (LA) and STS approaches in patients undergoing mitral valve surgery.Charts of patients who underwent mitral valve surgery by a single surgeon over a period of 20 years were reviewed retrospectively. A total of 319 patients (aged 42.9 ± 16.2 years) were studied. Surgical operations were carried out through the LA approach in 111 patients, and through the STS approach in 208 patients.The two groups were comparable in terms of patients' characteristics, but cardiopulmonary bypass and aortic cross-clamp times were longer in the STS approach group (P = .0005). No technical complications related to either approach occurred. Rates of re-exploration for postoperative bleeding, durations of intensive care unit (ICU) stay, in-hospital days, and mortality were comparable in both approaches. Statistical analyses indicated that a patient was more likely to maintain a preoperative sinus rhythm if the LA approach rather than the STS approach was used (P < .05). On the other hand, when the preoperative heart rhythm was atrial fibrillation, no significant difference in perioperative changes in heart rhythm was observed between the two approaches.This study confirms that the routine use of the STS approach is not associated with important adverse postoperative outcomes, but is associated with increased incidence of postoperative sinus node dysfunction in patients who were in sinus rhythm preoperatively.

Citation

ID: 106093
Ref Key: izzat2020comparisonjournal
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
106093
Unique Identifier:
10.1111/jocs.14603
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet