Wall stress analyses in patients with ≥5 cm versus

Wall stress analyses in patients with ≥5 cm versus <5 cm ascending thoracic aortic aneurysm.

Wang, Zhongjie;Flores, Nick;Lum, Matthew;Wisneski, Andrew D;Xuan, Yue;Inman, Justin;Hope, Michael D;Saloner, David A;Guccione, Julius M;Ge, Liang;Tseng, Elaine E;
The Journal of thoracic and cardiovascular surgery 2020
183
wang2020wallthe

Abstract

Current guidelines for elective surgery of ascending thoracic aortic aneurysms (aTAAs) use aneurysm size as primary determinant for risk stratification of adverse events. Biomechanically, dissection may occur when wall stress exceeds wall strength. Determining patient-specific aTAA wall stresses by finite element analysis can potentially predict patient-specific risk of dissection. This study compared peak wall stresses in patients with ≥5.0 cm versus <5.0 cm aTAAs to determine correlation between diameter and wall stress.Patients with aTAA ≥5.0 cm (n = 47) and <5.0 cm (n = 53) were studied. Patient-specific aneurysm geometries obtained from echocardiogram-gated computed tomography were meshed and prestress geometries determined. Peak wall stresses and stress distributions were determined using LS-DYNA finite element analysis software (LSTC Inc, Livermore, Calif), with user-defined fiber-embedded material models under systolic pressure.Peak circumferential stresses at systolic pressure were 530 ± 83 kPa for aTAA ≥5.0 cm versus 486 ± 87 kPa for aTAA <5.0 cm (P = .07), whereas peak longitudinal stresses were 331 ± 57 kPa versus 310 ± 54 kPa (P = .08), respectively. For aTAA ≥5.0 cm, correlation between peak circumferential stresses and size was 0.41, whereas correlation between peak longitudinal wall stresses and size was 0.33. However, for aTAA <5.0 cm, correlation between peak circumferential stresses and size was 0.23, whereas correlation between peak longitudinal stresses and size was 0.14.Peak patient-specific aTAA wall stresses overall were larger for ≥5.0 cm than aTAA <5.0 cm. Although some correlation between size and peak wall stresses was found in aTAA ≥5.0 cm, poor correlation existed between size and peak wall stresses in aTAA <5.0 cm. Patient-specific wall stresses are particularly important in determining patient-specific risk of dissection for aTAA <5.0 cm.

Citation

ID: 105176
Ref Key: wang2020wallthe
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
105176
Unique Identifier:
S0022-5223(20)30456-6
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet