D-optimal design as a useful tool response surface methodology for the optimization of signals from synchronous fluorescence prior to simultaneous determination of avanafil and tadalafil.

D-optimal design as a useful tool response surface methodology for the optimization of signals from synchronous fluorescence prior to simultaneous determination of avanafil and tadalafil.

Abdel-Raoof, Ahmed M;Said, Ragab A M;Emara, Mohamed S;El-Desouky, Ebrahim A;Abdelzaher, Ahmed M;Hasan, Mohamed A;Osman, Ayman E;
spectrochimica acta part a, molecular and biomolecular spectroscopy 2020 Vol. 235 pp. 118313
177
abdelraoof2020doptimalspectrochimica

Abstract

A rapid, smart and sensitive first derivative spectrofluorimetric method has been carried out for the simultaneous estimation of avanafil and tadalafil either in their pure form, tablet dosage form or spiked human plasma. The measurements of normal emission spectra or synchronous fluorescence intensity of both drugs show severe overlap which hindered their determination using normal fluorescence or synchronous intensity. Therefore, a highly sensitive first derivative synchronous fluorescence procedure was used to resolve this overlap. The method is based upon measurement of the amplitude of the first derivative of synchronous fluorescence intensity of both drugs at Δλ = 70 nm and at suitable wavelength of 396 nm and 364 nm for avanafil and tadalafil, respectively. Under the optimum conditions, the linear determination ranges are 50-1800 and 5-400 ng mL with a detection limit of 12.93 and 1.46 ng mL for avanafil and tadalafil, respectively. A response surface methodology was used for optimization using D-optimal design which can be used for determination of the exact optimum parameters specifically designed for this method. In addition; it is a good way to graphically clarify the relationship between various experimental variables and the synchronous fluorescence intensity.

Citation

ID: 103103
Ref Key: abdelraoof2020doptimalspectrochimica
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
103103
Unique Identifier:
S1386-1425(20)30291-2
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet