Disparity in implantable cardioverter defibrillator therapy among minority South Asians in the United Kingdom.

Disparity in implantable cardioverter defibrillator therapy among minority South Asians in the United Kingdom.

Mistry, Amar;Vali, Zakariyya;Sidhu, Bharat;Budgeon, Charley;Yuyun, Matthew F;Pooranachandran, Vivetha;Li, Xin;Newton, Michelle;Watts, Jamie;Khunti, Kamlesh;Samani, Nilesh J;Ng, G Andre;
heart (british cardiac society) 2020
227
mistry2020disparityheart

Abstract

There are large geographical differences in implantable cardioverter defibrillator (ICD) implantation rates for reasons not completely understood. In an increasingly multiethnic population, we sought out to investigate whether ethnicity influenced ICD implantation rates.This was a retrospective, cohort study of new ICD implantation or upgrade to ICD from January 2006 to February 2019 in recipients of Caucasian or South Asian ethnicity at a single tertiary centre in the UK. Data were obtained from a routinely collected local registry. Crude rates of ICD implantation were calculated for the population of Leicestershire county and were age-standardised to the UK population using the UK National Census of 2011.The Leicestershire population was 980 328 at the time of the Census, of which 761 403 (77.7%) were Caucasian and 155 500 (15.9%) were South Asian. Overall, 2650 ICD implantations were performed in Caucasian (91.9%) and South Asian (8.1%) patients. South Asians were less likely than Caucasians to receive an ICD (risk ratio (RR) 0.43, 95% CI 0.37 to 0.49, p<0.001) even when standardised for age (RR 0.75, 95% CI 0.74 to 0.75, p<0.001). This remained the case for primary prevention indication (age-standardised RR 0.91, 95% CI 0.90 to 0.91, p<0.001), while differences in secondary prevention ICD implants were even greater (age-standardised RR 0.49, 95% CI 0.48 to 0.50, p<0.001).Despite a universal and free healthcare system, ICD implantation rates were significantly lower in the South Asian than the Caucasian population residing in the UK. Whether this is due to cultural acceptance or an unbalanced consideration is unclear.

Citation

ID: 102847
Ref Key: mistry2020disparityheart
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
102847
Unique Identifier:
heartjnl-2019-315978
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet