Accuracy of medical billing data against the electronic health record in the measurement of colorectal cancer screening rates.

Accuracy of medical billing data against the electronic health record in the measurement of colorectal cancer screening rates.

Rudrapatna, Vivek A;Glicksberg, Benjamin S;Avila, Patrick;Harding-Theobald, Emily;Wang, Connie;Butte, Atul J;
BMJ open quality 2020 Vol. 9
252
rudrapatna2020accuracybmj

Abstract

Medical billing data are an attractive source of secondary analysis because of their ease of use and potential to answer population-health questions with statistical power. Although these datasets have known susceptibilities to biases, the degree to which they can distort the assessment of quality measures such as colorectal cancer screening rates are not widely appreciated, nor are their causes and possible solutions.Using a billing code database derived from our institution's electronic health records, we estimated the colorectal cancer screening rate of average-risk patients aged 50-74 years seen in primary care or gastroenterology clinic in 2016-2017. 200 records (150 unscreened, 50 screened) were sampled to quantify the accuracy against manual review.Out of 4611 patients, an analysis of billing data suggested a 61% screening rate, an estimate that matches the estimate by the Centers for Disease Control. Manual review revealed a positive predictive value of 96% (86%-100%), negative predictive value of 21% (15%-29%) and a corrected screening rate of 85% (81%-90%). Most false negatives occurred due to examinations performed outside the scope of the database-both within and outside of our institution-but 21% of false negatives fell within the database's scope. False positives occurred due to incomplete examinations and inadequate bowel preparation. Reasons for screening failure include ordered but incomplete examinations (48%), lack of or incorrect documentation by primary care (29%) including incorrect screening intervals (13%) and patients declining screening (13%).Billing databases are prone to substantial bias that may go undetected even in the presence of confirmatory external estimates. Caution is recommended when performing population-level inference from these data. We propose several solutions to improve the use of these data for the assessment of healthcare quality.

Access

Citation

ID: 102275
Ref Key: rudrapatna2020accuracybmj
Use this key to autocite in SciMatic or Thesis Manager

References

Blockchain Verification

Account:
NFT Contract Address:
0x95644003c57E6F55A65596E3D9Eac6813e3566dA
Article ID:
102275
Unique Identifier:
e000856
Network:
Scimatic Chain (ID: 481)
Loading...
Blockchain Readiness Checklist
Authors
Abstract
Journal Name
Year
Title
5/5
Creates 1,000,000 NFT tokens for this article
Token Features:
  • ERC-1155 Standard NFT
  • 1 Million Supply per Article
  • Transferable via MetaMask
  • Permanent Blockchain Record
Blockchain QR Code
Scan with Saymatik Web3.0 Wallet

Saymatik Web3.0 Wallet